Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RAINBOW CONSTRUCTION OF S. FLORIDA, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RAINBOW CONSTRUCTION OF S. FLORIDA, INC. in 231 GLENWOOD ST, PONTE VEDRA, FL 32081 (NAICS 238130). OSHA activity number 336779780.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rainbow Construction of S. Florida, INC. — free Get an email when a new federal OSHA severe-injury report for Rainbow Construction of S. Florida, INC. is published. One employer, no account, unsubscribe in one click.
Site address
231 GLENWOOD ST
City
PONTE VEDRA
State
FL
ZIP
32081
Mailing
3504 NW 84TH TER, CORAL SPRINGS, FL 33065
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
6
Ownership type
A

4 citations on file for this inspection.

1926.152 A01

Serious Gravity 5 1 instance 5 exposed
Issued
Nov 28, 2012
Penalty
Initial $1,360 · Current $1,360

Hazardous substances 1340

29 CFR 1926.152(a)(1):    Containers and portable tanks used for the storage and handling of flammable and combustible liquids were not approved:    a.   On or about October 10, 2012, at the northwest side of the house, a damaged portable tank was used for storage and handling of gasoline used to fuel the air compressor.
Recent events (1)
  • — Z (S) $1360

1926.501 B13

Serious Gravity 5 3 instances 3 exposed
Issued
Nov 28, 2012
Penalty
Initial $2,040 · Current $2,040
29 CFR 1926.501(b)(13):    Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):    a.   On or about October 10, 2012, on the front of the house, an employee installing framing did not use an adequate anchor point for his personal fall arrest system, exposing himself to a 9 feet fall hazard.    b.   On or about October 10, 2012, in the trusses on the southwest side of the roof, an employee installing framing was exposed to a 14 feet fall hazard in that he was not protected by a fall protection system.    c.   On or about October 10, 2012, at the south corner of the house, an employee installing framing was exposed to a 9 feet fall hazard in that he was not protected by a fall protection system.
Recent events (1)
  • — Z (S) $2040

1926.1053 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 28, 2012
Penalty
Initial $2,040 · Current $2,040
29 CFR 1926.1053(b)(1):    Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:    a.   On or about October 10, 2012, at the south corner of the house, the roof access ladder did not extend above the roof eave, exposing an employee to a 9 feet fall hazard.
Recent events (1)
  • — Z (S) $2040

1926.1053 B16

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 28, 2012
Penalty
Initial $2,040 · Current $2,040
29 CFR 1926.1053(b)(16):    Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired:    a.   On or about October 10, 2012, inside the house, a 20-foot aluminum extension ladder that framing employees used to access the trusses was missing a pawl on the fly section.