NAPERVILLE, IL —
OSHA Inspection: CHRIS ZAMASTIL
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CHRIS ZAMASTIL in 1521-1525, 1549 & 1551-1559 FAIRWAY DR., NAPERVILLE, IL 60563 (NAICS 238160). OSHA activity number 336803598.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CHRIS ZAMASTIL
- Site address
- 1521-1525, 1549 & 1551-1559 FAIRWAY DR.
- City
- NAPERVILLE
- State
- IL
- ZIP
- 60563
- Mailing
- 7907 WHITE OAKS DR., WONDER LAKE, IL 60097
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 7
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.404 B01 II
- Issued
- Jan 3, 2013
- Abate by
- Jan 15, 2013
- Penalty
- Initial $2,310 · Current $2,310
General-duty citation text
29 CFR 1926.404(b)(1)(ii): All 120-volt, single-phase 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, did not have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters. On October 11, 2012 employees were not protected by a ground fault circuit interrupter (GFCI) while working with power tools, exposing employees to the hazards associated with an electrical shock. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (1)
- — Z (S) $2310
1926.453 B02 IV
- Issued
- Jan 3, 2013
- Abate by
- Jan 15, 2013
- Penalty
- Initial $5,390 · Current $5,390
General-duty citation text
1926.453(b)(2)(iv) Employees were not standing firmly on the floor of the basket, and were standing on the edge of the basket. On October 11, 2012, employees were standing on the toe board outside the guard rails of an aerial lift, exposing employees to a fall hazard of over 25 feet. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (1)
- — Z (S) $5390
1926.453 B02 V
- Issued
- Jan 3, 2013
- Abate by
- Jan 15, 2013
- Penalty
- Initial $5,390 · Current $5,390
General-duty citation text
1926.453(b)(2)(v): A body belt shall was not worn and a lanyard attached to the boom or basket when working from an aerial lift. Note to paragraph (b)(2)(v): As of January 1, 1998, subpart M of this part (1926.502(d)) provides that body belts are not acceptable as part of a personal fall arrest system. The use of a body belt in a tethering system or in a restraint system is acceptable and is regulated under 1926.502(e). On October 11, 2012, employees were not protected from a fall while working from an aerial lift, exposing employees to a fall of over 25 feet. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (1)
- — Z (S) $5390
1926.453 B02 VI
- Issued
- Jan 3, 2013
- Abate by
- Jan 15, 2013
- Penalty
- Initial $5,390 · Current $5,390
General-duty citation text
1926.453(b)(2)(vi) Boom and basket load limits specified by the manufacturer were exceeded. On October 11, 2012, employees were exposed to the hazards associated with an aerial lift collapse as they worked from an overloaded aerial lift. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (1)
- — Z (S) $5390
1926.1053 B01
- Issued
- Jan 3, 2013
- Abate by
- Jan 15, 2013
- Penalty
- Initial $3,850 · Current $3,850
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: On October 11, 2102 employees were allowed to use an extension ladder that did not extend three feet past the upper landing, exposing employees to a fall hazard of over 25 feet. Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (1)
- — Z (S) $3850
1926.501 B13
- Issued
- Jan 3, 2013
- Abate by
- Jan 15, 2013
- Penalty
- Initial $53,900 · Current $53,900
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On October 11, 2012, employees working at 1521-1525 Fairway Drive were allowed to install roofing material without fall protection, exposing employees to a fall hazard of over 25 feet. b) On October 11, 2012, employees working at 1551-1559 Fairway Drive were allowed to install roofing material without fall protection, exposing employees to a fall hazard of over 25 feet. c) On October 11, 2012, employees working at 1549 Fairway Drive were allowed to stage roofing material without fall protection, exposing employees to a fall hazard of over 25 feet. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (1)
- — Z (W) $53900
More inspections at Chris Zamastil
View Chris Zamastil's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336803598.