OSHA Inspection: CHRIS ZAMASTIL

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CHRIS ZAMASTIL in 1521-1525, 1549 & 1551-1559 FAIRWAY DR., NAPERVILLE, IL 60563 (NAICS 238160). OSHA activity number 336803598.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Chris Zamastil — free Get an email when a new federal OSHA severe-injury report for Chris Zamastil is published. One employer, no account, unsubscribe in one click.
Establishment
CHRIS ZAMASTIL
Site address
1521-1525, 1549 & 1551-1559 FAIRWAY DR.
City
NAPERVILLE
State
IL
ZIP
60563
Mailing
7907 WHITE OAKS DR., WONDER LAKE, IL 60097
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
7
Ownership type
A

6 citations on file for this inspection.

1926.404 B01 II

Serious Gravity 1 1 instance 7 exposed
Issued
Jan 3, 2013
Abate by
Jan 15, 2013
Penalty
Initial $2,310 · Current $2,310
29 CFR 1926.404(b)(1)(ii): All 120-volt, single-phase 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, did not have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.    On October 11, 2012 employees were not protected by a ground fault circuit interrupter (GFCI) while working with power tools, exposing employees to the hazards associated with an electrical shock.    Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (1)
  • — Z (S) $2310

1926.453 B02 IV

Serious Gravity 10 1 instance 3 exposed
Issued
Jan 3, 2013
Abate by
Jan 15, 2013
Penalty
Initial $5,390 · Current $5,390
1926.453(b)(2)(iv)    Employees were not standing firmly on the floor of the basket, and were standing on the edge of the basket.    On October 11, 2012, employees were standing on the toe board outside the guard rails of an aerial lift, exposing employees to a fall hazard of over 25 feet.    Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (1)
  • — Z (S) $5390

1926.453 B02 V

Serious Gravity 10 1 instance 4 exposed
Issued
Jan 3, 2013
Abate by
Jan 15, 2013
Penalty
Initial $5,390 · Current $5,390
1926.453(b)(2)(v):    A body belt shall was not worn and a lanyard attached to the boom or basket when working from an aerial lift.    Note to paragraph (b)(2)(v): As of January 1, 1998, subpart M of this part (1926.502(d)) provides that body belts are not acceptable as part of a personal fall arrest system. The use of a body belt in a tethering system or in a restraint system is acceptable and is regulated under 1926.502(e).    On October 11, 2012, employees were not protected from a fall while working from an aerial lift, exposing employees to a fall of over 25 feet.    Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (1)
  • — Z (S) $5390

1926.453 B02 VI

Serious Gravity 10 1 instance 5 exposed
Issued
Jan 3, 2013
Abate by
Jan 15, 2013
Penalty
Initial $5,390 · Current $5,390
1926.453(b)(2)(vi)    Boom and basket load limits specified by the manufacturer were exceeded.    On October 11, 2012, employees were exposed to the hazards associated with an aerial lift collapse as they worked from an overloaded aerial lift.     Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (1)
  • — Z (S) $5390

1926.1053 B01

Serious Gravity 5 1 instance 7 exposed
Issued
Jan 3, 2013
Abate by
Jan 15, 2013
Penalty
Initial $3,850 · Current $3,850
29 CFR 1926.1053(b)(1):     Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:    On October 11, 2102 employees were allowed to use an extension ladder that did not extend three feet past the upper landing, exposing employees to a fall hazard of over 25 feet.    Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (1)
  • — Z (S) $3850

1926.501 B13

Willful Gravity 10 1 instance 11 exposed
Issued
Jan 3, 2013
Abate by
Jan 15, 2013
Penalty
Initial $53,900 · Current $53,900
29 CFR 1926.501(b)(13):     Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):     a) On October 11, 2012, employees working at 1521-1525 Fairway Drive were allowed to install roofing material without fall protection, exposing employees to a fall hazard of over 25 feet.    b)  On October 11, 2012, employees working at 1551-1559 Fairway Drive were allowed to install roofing material without fall protection, exposing employees to a fall hazard of over 25 feet.    c) On October 11, 2012, employees working at 1549 Fairway Drive were allowed to stage roofing material without fall protection, exposing employees to a fall hazard of over 25 feet.      Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (1)
  • — Z (W) $53900

View Chris Zamastil's full OSHA safety record →