WILLIAMSPORT, PA —
OSHA Inspection: SUSQUEHANNA SUPPLY COMPANY
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SUSQUEHANNA SUPPLY COMPANY in ARCH STREET, WILLIAMSPORT, PA 17702 (NAICS 237310). OSHA activity number 336845383.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SUSQUEHANNA SUPPLY COMPANY
- Site address
- ARCH STREET
- City
- WILLIAMSPORT
- State
- PA
- ZIP
- 17702
- Mailing
- 2 ROSE ST, WILLIAMSPORT, PA 17701
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237310
- Employees
- 12
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.600 A06 I
- Issued
- Dec 13, 2012
- Penalty
- Initial $4,900 · Current $3,000 Reduced
General-duty citation text
29 CFR 1926.600(a)(6)(i): For lines rated 50kV or below, a minimum of 10 feet was not maintained between the energized line and the equipment. a) Arch Street, Williamsport, PA; A Caterpillar Model 325 Serial Number 07M00547 was operating less than 10 feet from a 240 volt live residential drop line while setting concrete forms, on or about 09/27/12. Abatement Observed During Inspection - No Abatement Certification Required
Recent events (2)
- — I (S) $3000
- — Z (S) $4900
1926.1408 D01
- Issued
- Dec 13, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1408(d)(1): The equipment, load line, or load (including rigging and lifting accessories) was below a power line. a) Arch Street, Williamsport, PA; A Link-Belt FMC Model HSP-8020 Serial Number 47HO-1174H crane was used to transport concrete within 10 feet under a 240 volt live home service drop line, on or about 10/04/12. Abatement Observed During Inspection - No Abatement Certification Required
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1417 A
- Issued
- Dec 13, 2012
- Penalty
- Initial $2,380 · Current $2,000 Reduced
General-duty citation text
29 CFR 1926.1417(a): 29 CFR 1926.1417(a): The employer did not comply with all manufacturer procedures applicable to the operational functions of equipment, including its use with attachments. a) Arch Street, Williamsport, PA; The anti-two-blocking device on the Grove RT 750 Serial Number 220232 crane was disconnected to strip concrete forms, on or about 10/04/12. Abatement Observed During Inspection - No Abatement Certification Required
Recent events (2)
- — I (S) $2000
- — Z (S) $2380
More inspections at Susquehanna Supply Company
View Susquehanna Supply Company's full OSHA safety record →
More inspections in this industry (NAICS 237310)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336845383.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.