COLUMBUS, NE —
OSHA Inspection: 3D DESIGNS, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of 3D DESIGNS, INC. in 1520 25TH ST., COLUMBUS, NE 68601 (NAICS 332322). OSHA activity number 336848783.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- 3D DESIGNS, INC.
- Site address
- 1520 25TH ST.
- City
- COLUMBUS
- State
- NE
- ZIP
- 68601
- Mailing
- 1520 25TH ST., COLUMBUS, NE 68601
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332322
- Employees
- 15
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.134 C01
- Issued
- Dec 10, 2012
- Abate by
- Jan 29, 2013
- Penalty
- Initial $1,360 · Current $952 Reduced
0689A102
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use. A written respiratory protection program was not implemented and not available upon agency request. Employee(s) were required to to wear a powered air purifying welding helmet-type respirator for aluminum wire feed welding.
Recent events (2)
- — I (S) $952
- — Z (S) $1360
1910.134 E01
- Issued
- Dec 10, 2012
- Abate by
- Jan 29, 2013
- Penalty
- Initial $0 · Current $0
0689A102
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace. A required medical evaluation had not been conducted as required by the standard. Employee(s) were required to to wear a powered air purifying welding helmet-type respirator for aluminum wire feed welding.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Dec 10, 2012
- Abate by
- Jan 29, 2013
- Penalty
- Initial $1,700 · Current $1,190 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. The point of operation of equipment including, but not limited to the Primeline press brake and the AccurPress, were not guarded.
Recent events (2)
- — I (S) $1190
- — Z (S) $1700
More inspections at 3D Designs, INC.
View 3D Designs, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332322)
More inspections in NE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336848783.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.