Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HENNINGSEN FOODS INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of HENNINGSEN FOODS INC. in 402 N. 3RD STREET, NORFOLK, NE 68702 (NAICS 311615). OSHA activity number 336895180.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Henningsen Foods INC. — free Get an email when a new federal OSHA severe-injury report for Henningsen Foods INC. is published. One employer, no account, unsubscribe in one click.
Site address
402 N. 3RD STREET
City
NORFOLK
State
NE
ZIP
68702
Mailing
402 N. 3RD STREET, NORFOLK, NE 68702
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311615
Employees
44
Ownership type
A

8 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 27, 2013
Abate by
Apr 1, 2013
Penalty
Initial $6,300 · Current $6,300
OSH ACT of 1970 Section (5)(a)(1):     Section 5(a)(1) of the Occupational Safety and Health Act of 1970:    The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees are exposed to explosion and/or burn hazards.      The employer has failed to ensure the personnel performing maintenance activities on direct fired liquid petroleum gas vaporizer units were knowledgeable as to the manufacturers requirements of their use and maintenance.   The lack of knowledge allowed an overpressure situation to occur during a purging process.  The released gas was then ignited creating a flash fire which injured two maintenance personnel.      AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO CORRECT THIS HAZARD IS:    (a)  Ensure that only qualified and knowledgeable personnel perform any operations, to include maintenance, on the direct fired LP gas vaporizer units.     (b)  Conduct training with any personnel that work with the LP gas vaporizer units which includes a review of the operators manual and specifically any warnings contained therein.  This training would include any of the manufacturers required steps for the operation of unit.    Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful.  The abatement certification sheet is enclosed with the citations.
Recent events (2)
  • — I (S) $6300
  • — Z (S) $6300

5(a)(1)

Serious Gravity 5 3 instances 3 exposed
Issued
Feb 27, 2013
Abate by
May 3, 2013
Penalty
Initial $4,500 · Current $4,500
OSH ACT of 1970 Section (5)(a)(1):     The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees are exposed to crushing hazards as a result of possible hoist failure.      At the following locations, the employer failed to ensure that the hoists were inspected in a manner that met the requirements outlined in ANSI B30.16.  Specifically, the quarterly inspections did not go beyond a visual inspection of the hoist housings and excluded the internal components.      a)	G-Dryer Room; CM 1 ton hoist    b)	 2nd Floor Cooker Room; 2 CM hoists    c)	 Maintenance Shop; Robbins & Meyers Inc hoist      AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO CORRECT THIS HAZARD IS:    (a)  Ensure that maintenance personnel are trained on the requirements for hoist inspection outlined in ANSI B30.16.       (b)  Conduct hoist inspections as outlined in the ANSI standard at the prescribed intervals to ensure that the hoists are maintained in a safe and serviceable condition.        Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful.  The abatement certification sheet is enclosed with the citations.
Recent events (2)
  • — I (S) $4500
  • — Z (S) $4500

1910.146 C07 III

Serious Gravity 5 1 instance 4 exposed
Issued
Feb 27, 2013
Abate by
May 31, 2013
Penalty
Initial $4,500 · Current $4,500
29 CFR 1910.146(c)(7)(iii):     The employer did not document the basis for determining that all hazards in a permit space had been eliminated, through a written certification that contained the date, the location of the space, and the signature of the person making the determination:    Jobsite located at 402 N. 3rd Street, Norfolk, NE:  The employer failed to document the declassification of permit-required confined spaces prior to allowing employees to enter.  This would include the F and E product dryers.      Abatement certification is required for this violation.  The abatement certification sheet is enclosed with the citations.
Recent events (2)
  • — I (S) $4500
  • — Z (S) $4500

1910.147 C06 I

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 27, 2013
Abate by
Apr 1, 2013
Penalty
Initial $4,500 · Current $4,500
29 CFR 1910.147(c)(6)(i):     The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    Jobsite located at 402 N. 3rd Street, Norfolk NE.   The employer failed to conduct a periodic inspection of the energy control procedures as outlined in the standard. The procedures cover equipment including but not limited to the hotwell pump and drying homogenizer.       Abatement certification is required for this violation.  The abatement certification sheet is enclosed with the citations.
Recent events (2)
  • — I (S) $4500
  • — Z (S) $4500

1910.147 C06 II

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 27, 2013
Abate by
Apr 1, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(ii):     The periodic inspection certification of energy control procedures did not contain the required documentation on identification of the machine or equipment, inspection date, employees included, and the person performing the inspection:    Jobsite located at 402 N. 3rd Street, Norfolk NE:  The employer does not have a written certification that identifies the employees included or the person performing the inspection.        Abatement certification is required for this violation.  The abatement certification sheet is enclosed with the citations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 C02 I

Serious Gravity 5 2 instances 2 exposed
Issued
Feb 27, 2013
Abate by
Apr 1, 2013
Penalty
Initial $3,600 · Current $3,600
29 CFR 1910.219(c)(2)(i):     Exposed part(s) of horizontal shafting seven -7 feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting:      At the following locations, the company did not provide guarding for rotating shafts:    a)  E-Processing Room; Lighting Mixer shaft    b)  E-Dryer Cooking Room; Shafts at both ends of the Continuous Cooker are noted guarded.      Abatement certification is required for this violation.  The abatement certification sheet is enclosed with the citations.
Recent events (2)
  • — I (S) $3600
  • — Z (S) $3600

1910.305 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 27, 2013
Abate by
Feb 28, 2014
Penalty
Initial $3,600 · Current $3,600
29 CFR 1910.305(e)(1):     Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations were not installed to prevent moisture or water from entering and accumulating within the enclosures:    3rd Floor F-Dryer Room:  The electrical panels located inside of the room are not designed for wet or damp locations and could allow water to enter the enclosures.  Some of the observed panels are showing extensive corrosion.      Abatement certification is required for this violation.  The abatement certification sheet is enclosed with the citations.
Recent events (2)
  • — I (S) $3600
  • — Z (S) $3600

1910.178 L04 III

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 27, 2013
Abate by
Apr 1, 2013
Penalty
Initial $18,000 · Current $7,000 Reduced
29 CFR 1910.178(l)(4)(iii):     The employer did not perform an evaluation of each powered industrial truck operators performance at least once every three years.      Throughout the Facility:  The employer failed to ensure that each operator of a powered industrial truck was evaluated every three years as required.  Employees have been trained (5 years prior to the inspection) but not re-certified.      Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful.  The abatement certification sheet is enclosed with the citations.
Recent events (2)
  • — I (S) $7000
  • — Z (R) $18000