Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WORTHINGTON CYLINDERS

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of WORTHINGTON CYLINDERS in 795 BARKLEY DRIVE, NEW ALBANY, MS 38652 (NAICS 331316). OSHA activity number 336992417.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Worthington Cylinders — free Get an email when a new federal OSHA severe-injury report for Worthington Cylinders is published. One employer, no account, unsubscribe in one click.
Site address
795 BARKLEY DRIVE
City
NEW ALBANY
State
MS
ZIP
38652
Mailing
795 BARKLEY DRIVE, NEW ALBANY, MS 38652
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331316
Employees
200
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 II B

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 9, 2013
Abate by
Feb 27, 2013
Penalty
Initial $3,038 · Current $1,823 Reduced
29 CFR 1910.147(c)(4)(ii)(B):     The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy.        (a) Press Area - On or about October 31, 2012 specific lockout procedures had not been developed for the presses and other equipment in the facility.
Recent events (2)
  • — I (S) $1822.8
  • — Z (S) $3038

1910.303 F02

Serious Gravity 1 1 instance 2 exposed
Issued
Jan 9, 2013
Abate by
Feb 5, 2013
Penalty
Initial $1,823 · Current $1,094 Reduced
29 CFR 1910.303(f)(2):     Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:      (a) Line 14 - On or about October 31, 2012 the RP7 electric panel was not labeled to identify what each disconnect controls.
Recent events (2)
  • — I (S) $1093.8
  • — Z (S) $1823

1910.146 K01 V

Other-than-serious 1 instance 2 exposed
Issued
Jan 9, 2013
Abate by
Feb 27, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.146(k)(1)(v):     The employer who had designated rescue and emergency services did not provide the selected rescue team or service  with access to all permit spaces from which rescue could  be necessary, so that the rescue service could develop    (a) Press 82 - On or about October 26, 2012 the local fire department had not been out to access and evaluate the areas where they may have to conduct rescue.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 B02

Other-than-serious 1 instance 2 exposed
Issued
Jan 9, 2013
Abate by
Feb 27, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2):     Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling    (a) Hydro Line 102- On or about October 31, 2012 the portable power tap in use was not approved for industrial use.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Worthington Cylinders's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336992417.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.