Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PERFORMANCE ROOFING SYSTEMS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PERFORMANCE ROOFING SYSTEMS, INC. in 28557 N. BALLARD DR., LAKE FOREST, IL 60045 (NAICS 238160). OSHA activity number 336997382.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Performance Roofing Systems, INC. — free Get an email when a new federal OSHA severe-injury report for Performance Roofing Systems, INC. is published. One employer, no account, unsubscribe in one click.
Site address
28557 N. BALLARD DR.
City
LAKE FOREST
State
IL
ZIP
60045
Mailing
P.O. BOX 187, RICHFIELD, WI 53076
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
2
Ownership type
A

3 citations on file for this inspection.

1926.502 F01

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 7, 2012
Abate by
Nov 14, 2012
Penalty
Initial $4,410 · Current $2,205 Reduced
29 CFR 1926.502(f)(1): Warning lines were not erected around all sides of the roof work area:    a) Warning lines were not erected around all sides of the roof work area.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $2205
  • — Z (S) $4410

1926.502 F01 III

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 7, 2012
Abate by
Nov 14, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.502(f)(1)(iii): Points of access, material handling areas, storage areas, and/or hoisting areas were not connected to the work area by an access path formed by two warning lines:    a) Warning lines were not used to create access paths connecting the work area to the point of access along the roof edge.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B10

Repeat Gravity 10 2 instances 3 exposed
Issued
Nov 7, 2012
Abate by
Nov 14, 2012
Penalty
Initial $8,820 · Current $3,525 Reduced
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system:    a) Employees were not protected from the hazard of falling approximately 19 feet from the roof edge while engaged in roofing activities without the benefit of fall protection or safety monitoring.     Performance Roofing Systems, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501 (b)(10) which was contained in OSHA inspection number 109660, citation 1, item 1, issued on January 17, 2012, and became final order on or about February 8, 2012.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (R) $3525
  • — Z (R) $8820

View Performance Roofing Systems, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336997382.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.