Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GENERAL MOTORS CORPORATION

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of GENERAL MOTORS CORPORATION in 2300 HALLOCK YOUNG RD., WARREN, OH 44482 (NAICS 336211). OSHA activity number 337004998.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch General Motors Corporation — free Get an email when a new federal OSHA severe-injury report for General Motors Corporation is published. One employer, no account, unsubscribe in one click.
Site address
2300 HALLOCK YOUNG RD.
City
WARREN
State
OH
ZIP
44482
Mailing
2300 HALLOCK YOUNG RD., WARREN, OH 44482
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336211
Employees
1800
Ownership type
A

3 citations on file for this inspection.

1910.157 G02

Other-than-serious 1 instance 1800 exposed
Issued
Mar 1, 2013
Abate by
Sep 13, 2013
Penalty
Initial $3,300 · Current $0 Reduced
29 CFR 1910.157(g)(2):     The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter:    Portable fire extinguishers were available for employee use, but annual training was not provided as required.    Note the employer may exercise one of the following options:    1.	Provide portable fire extinguishers as specified in 29 CFR 1910.157(c)(1), meet the distribution requirements per 29 CFR 1910.157(d) (75 to the nearest extinguisher for Class A fires and 50 to the nearest unit for Class B fires), and provide training and education for all employees in the use of such equipment and the hazards associated with incipient stage fire fighting as specified in 29 CFR 1910.157(g).  The other sections of 29 CFR also apply.    2.	Provide extinguishers as specified in 29 CFR 1910.157(c)(1), designate certain employees to be the only employees authorized to use such equipment and require all other employees to immediately evacuate upon the sound of the fire alarm, establish this in writing in an emergency action plan as outlined in 29 CFR 1910.38(a) and train/educate designated employees per 1910.157(g).  Utilizing this option exempts the employer from distribution requirements of 29 CFR 1910.157(d).    3.	Establish a written fire safety policy which requires the immediate and total evacuation of employees from the workplace upon the sounding of a fire alarm signal.  This policy shall include an emergency action plan and a fire prevention plan as specified in 29 CFR 1910.38(a) and 29 CFR 1910.39(a).  Utilizing this option exempts the employer from the requirements of 29 CFR 1910.157 to include the need for providing portable fire equipment unless a specific standard requires that a portable fire extinguisher be provided (such as those requirements in 29 CFR 1910.106/107 related to the use/storage of flammable/combustible liquids).  If extinguishers are provided, but not intended for employee use, 29 CFR 1910.157(e) and (f) are still applicable (inspection, maintenance, and testing of equipment).
Recent events (3)
  • — F (O) $0
  • — C (S) $3300
  • — Z (S) $3300

1910.252 A01 I

Serious Gravity 5 1 instance 1000 exposed
Issued
Mar 1, 2013
Abate by
Sep 13, 2013
Penalty
Initial $6,600 · Current $6,600
29 CFR 1910.252(a)(1)(i):     When the object to be welded or cut could not be readily moved, all movable fire hazards in the vicinity were not taken to a safe place:    On or about December 13, 2012, the employer did not remove all of the cardboard from around the welding areas of the body shop.  At about 6 am the morning of December 13, 2012, there was a fire in the body shop that started from the weld expulsion igniting the cardboard.
Recent events (3)
  • — F (S) $6600
  • — C (S) $6600
  • — Z (S) $6600

1910.252 B02 III

Deleted Serious Gravity 1 1 instance 20 exposed
Issued
Mar 1, 2013
Abate by
Apr 5, 2013
Penalty
Initial $3,300 · Current $0 Reduced
29 CFR 1910.252(b)(2)(iii):     Workers and other persons adjacent to the welding area were not were not protected from the rays by noncombustible or flameproof screens or shields:    On or about October 23, 2012, in the West Plant, at columns DD3-DD4, by the Hospital entrance, the robotic MIG welding cell's exit and entry points did not have welding screens or shields up to protect employees who would be walking by the areas during production.
Recent events (3)
  • — F (S) $0
  • — C (S) $3300
  • — Z (S) $3300

View General Motors Corporation's full OSHA safety record →