On , OSHA opened an unprogrammed Other safety inspection of MILLINGTON LOCKWOOD, INC. in MOOG INC. CORPORATE HEADQUARTERS BUILDING SENECA & JAMISON ROADS, ELMA, NY 14059 (NAICS 238390). OSHA activity number 337009187.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Millington Lockwood, INC. — free Get an email when a new federal OSHA severe-injury report for Millington Lockwood, INC. is published. One employer, no account, unsubscribe in one click.
Site address
MOOG INC. CORPORATE HEADQUARTERS BUILDING SENECA & JAMISON ROADS
City
ELMA
State
NY
ZIP
14059
Mailing
3901 GENESEE ROAD, SUITE 800, BUFFALO, NY 14225
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238390
Employees
7
Ownership type
A

2 citations on file for this inspection.

1926.404 A02

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 5, 2012
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1926.404(a)(2):     A grounded conductor was attached to a terminal or lead so as to reverse designated polarity:    a) On or about 10/16/12, at the Moog Inc. Corporate Headquarters Construction Site, Elma, NY: Employee used a DeWalt Compound Mitre Saw to cut metal parts. The Mitre Saw was connected to 120 volt-ac power via a series of two extension cords, the first of which was plugged into a receptacle in a 4-receptacle outlet box mounted on   a wooden 2x4 in the lower level main office area inside thebuilding. The first cord in the series was a short black GFCI 3-Way which belonged to another contractor. All 3 receptacles on this cord had "reversed polarity".    NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1926.404 F06

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 5, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(6):     The path to ground from circuits, equipment, or enclosures was not permanent and continuous:       a) On or about 10/16/12, at the Moog Inc. Corporate Headquarters Construction Site, Elma, NY: Employee used a DeWalt Compound Mitre Saw to cut metal parts. The Mitre Saw was connected to 120 volt-ac power via a series of two extension cords, the first of which was plugged into a receptacle in a 4-receptacle outlet box mounted on a wooden 2x4 in the lower level main office area inside thebuilding. The first cord in the series was a short black GFCI 3-Way which belonged to another contractor. All 3 receptacles on this cord were "ungrounded" because the grounding prong was missing on the plug of this cord.      NO ABATEMENT CERTIFICATION REQUIRED