DORAL, FL —
OSHA Inspection: SOLAR ERECTORS U.S. INC.
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of SOLAR ERECTORS U.S. INC. in 3800 NW 115TH AVE., DORAL, FL 33178 (NAICS 327390). OSHA activity number 337060180.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SOLAR ERECTORS U.S. INC.
- Site address
- 3800 NW 115TH AVE.
- City
- DORAL
- State
- FL
- ZIP
- 33178
- Mailing
- 10501 NW 121 WAY, MEDLEY, FL 33178
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327390
- Employees
- 65
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Apr 8, 2013
- Abate by
- Apr 25, 2013
- Penalty
- Initial $6,930 · Current $6,930
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees when they were exposed to struck-by and caught-in-between hazards: On or about 10/10/12, at the above addressed jobsite, employees were exposed to the risk of being struck by collapsing pre-cast structural members due to not ensuring that column B-3 was properly grouted. Among other methods, one feasible and acceptable abatement method to correct this hazard is to follow and implement the Coreslab Erection Drawing E0.0 General Notes, Section 3.2 Welding, which requires welding of connections shall follow closely behind the erection of units. Also, ensure Section 3.4 Grout and Solar Erectors erection procedure in the column section, item #4 are followed. NOTE: ABATEMENT CERTIFICATION AND DOCUMENTATION IS REQUIRED FOR THIS ITEM.
Recent events (2)
- — I (S) $6930
- — Z (S) $6930
1926.704 A
- Issued
- Apr 8, 2013
- Abate by
- Apr 25, 2013
- Penalty
- Initial $6,930 · Current $6,930
General-duty citation text
29 CFR 1926.704(a): Precast concrete wall units, structural framing and tilt-up wall panels were not adequately supported to prevent overturning and to prevent collapse until permanent connections were completed: On or about 10/10/12, at the above addressed jobsite, employees were exposed to the risk of being struck-by collapsing pre-cast structural members due to column B-2 not being braced. NOTE: ABETEMENT CERTIFICATION AND DOCUMENTATION IS REQUIRED FOR THIS ITEM.
Recent events (2)
- — I (S) $6930
- — Z (S) $6930
More inspections at Solar Erectors U.S. INC.
View Solar Erectors U.S. INC.'s full OSHA safety record →
More inspections in this industry (NAICS 327390)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337060180.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.