EL PASO, TX —
OSHA Inspection: DISH NETWORK
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of DISH NETWORK in 1285 JOE BATTLE BOULEVARD SUITE A, EL PASO, TX 79936 (NAICS 517110). OSHA activity number 337089189.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DISH NETWORK
- Site address
- 1285 JOE BATTLE BOULEVARD SUITE A
- City
- EL PASO
- State
- TX
- ZIP
- 79936
- Mailing
- 1285 JOE BATTLE BOULEVARD, EL PASO, TX 79936
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 517110
- Employees
- 4027
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.303 A
- Issued
- Feb 22, 2013
- Abate by
- Apr 18, 2013
- Penalty
- Initial $7,000 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.303(a) The conductors and equipment required or permitted by this subpart were not acceptable, as defined in Sec. 1910.399. It was found on October 12, 2012, the employer designed, produced, and installed unapproved equipment. A device called the Smart Box 3 was not approved by a Nationally Recognized Testing Laboratory and was not tested and examined for workplace safety, nor was the Smart Box 3 determined to be safe on the basis of test data. Subsequently, the completed device design did not account for a reverse polarity wiring occurring when the Smart Box 3 casing was created.
Recent events (3)
- — R (S) $3500
- — C (S) $7000
- — Z (S) $7000
1910.304 A02
- Issued
- Feb 22, 2013
- Abate by
- Mar 6, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(a)(2) A grounded conductor was attached to a terminal or lead so as to reverse designated polarity. It was found on October 12, 2012, the employer designed, produced, and installed unapproved equipment. Through the development and manufacturing process of the Smart Box 3, the design of the casing for the smart box did not account for the power boot to be turned 180 degrees on the vertical, resulting in switching the neutral and hot conductors for the system. No safety testing had been done once a complete Smart Box 3 unit was created to determine if the completed, end user piece of equipment would be safe for employees to use.
Recent events (3)
- — R (S) $0
- — C (S) $0
- — Z (S) $0
1910.304 G05
- Issued
- Feb 22, 2013
- Abate by
- Mar 6, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(g)(5) The path to ground from circuits, equipment, and enclosures were not effective. It was found on October 12, 2012, the grounding path from the receivers to the Smart Box to the Smart Tree was not effective exposing employees to a shock hazard.
Recent events (3)
- — R (S) $0
- — C (S) $0
- — Z (S) $0
1910.305 G02 II
- Issued
- Feb 22, 2013
- Abate by
- Apr 18, 2013
- Penalty
- Initial $7,000 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(ii) Flexible cords were not used in continuous lengths or without splices or taps. It was found on October 12, 2012, the employer had attempted to correct a reverse polarity wiring of their Smart Box 3 equipment by splicing the flexible cord used to power the equipment, reversing the conductors to eliminate the reversed polarity, then securing the conductors together with electrical wing nuts, then using red electrical tape to insulate the wiring.
Recent events (3)
- — R (O) $2000
- — C (S) $7000
- — Z (S) $7000
1910.334 A03 III
- Issued
- Feb 22, 2013
- Abate by
- Apr 18, 2013
- Penalty
- Initial $7,000 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.334(a)(3)(iii) Adapters which interrupt the continuity of the equipment grounding connection may not be used. It was found on November 6, 2012, the employer had installed 3-2 adapter on electrical outlets which employees use to plug in receivers to be tested. The adaptor does not have a grounding pin and is instead equipped with a grounding screw tab which is to be screwed into the wall plate, center screw of the outlet. During the walk around several adaptors were observed to have their grounding tab severely damaged, some completely uninstalled from the screw plate.
Recent events (3)
- — R (S) $3500
- — C (S) $7000
- — Z (S) $7000
More inspections at Dish Network
View Dish Network's full OSHA safety record →
More inspections in this industry (NAICS 517110)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337089189.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.