Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MANTALINE CORPORATION

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of MANTALINE CORPORATION in 4754 EAST HIGH STREET, MANTUA, OH 44255 (NAICS 326299). OSHA activity number 337145981.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mantaline Corporation — free Get an email when a new federal OSHA severe-injury report for Mantaline Corporation is published. One employer, no account, unsubscribe in one click.
Site address
4754 EAST HIGH STREET
City
MANTUA
State
OH
ZIP
44255
Mailing
4754 EAST HIGH STREET, MANTUA, OH 44255
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326299
Employees
130
Ownership type
A

14 citations on file for this inspection.

1910.22 A01

Serious Gravity 1 1 instance 10 exposed
Issued
Apr 26, 2013
Abate by
May 6, 2013
Penalty
Initial $2,700 · Current $1,620 Reduced
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly to the extent that the nature of the work allowed:    The employer did not keep clean work surfaces and electrical panels from the buildup of the flock material.
Recent events (2)
  • — I (S) $1620
  • — Z (S) $2700

1910.24 B

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 26, 2013
Abate by
Apr 26, 2013
Penalty
Initial $2,700 · Current $1,620 Reduced
29 CFR 1910.24(b): Fixed stairs shall be provided for access from one structure level to another where operations necessitate regular travel between levels, and for access to operating platforms at any equipment which requires attention routinely during operations:     Employees used a 5-gallon plastic bucket in the flock room to gain access to the top bin of flock.
Recent events (2)
  • — I (S) $1620
  • — Z (S) $2700

1910.106 E02 IV A

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 26, 2013
Abate by
Apr 26, 2013
Penalty
Initial $2,700 · Current $1,620 Reduced
29 CFR 1910.106(e)(2)(iv)(a): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be kept in covered containers when not actually in use:    Approximately 1 liter of n-butyl acetate, a Class 1 C flammable with a flashpoint of 75 degrees, was left uncovered on a work desk in the flock line.
Recent events (2)
  • — I (S) $1620
  • — Z (S) $2700

1910.106 E09 III

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.106(e)(9)(iii): "Waste and residue." Combustible waste material and residues in a building or unit operating area shall be kept to a minimum, stored in covered metal receptacles and disposed of daily:  In the flock area, rags impregnated with n-butyl acetate, a Class 1C flammable, were kept in the open on a table.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.106 E06 II

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 26, 2013
Abate by
May 8, 2013
Penalty
Initial $2,700 · Current $1,620 Reduced
29 CFR 1910.106(e)(6)(ii): Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected:    N-butyl acetate, a class IC flammable with a flashpoint of 75 degree Fahrenheit, was dispensed from a primary container to a secondary container, and then to a third container, all without bonding.
Recent events (2)
  • — I (S) $1620
  • — Z (S) $2700

1910.134 C01

Deleted Serious Gravity 1 1 instance 2 exposed
Issued
Apr 26, 2013
Abate by
May 31, 2013
Penalty
Initial $2,700 · Current $0 Reduced
29 CFR 1910.134(c)(1): In any workplace where respirators are necessary to protect the health of the employee or whenever respirators are required by the employer, the employer shall establish and implement a written respiratory protection program with worksite-specific procedures. The program shall be updated as necessary to reflect those changes in workplace conditions that affect respirator use:  There was no written respiratory protection program at the facility where at least one employee working on the flockline was required by the employer to wear a dust mask to perform flockline duties.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2700

1910.147 C04 I

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Apr 26, 2013
Abate by
May 31, 2013
Penalty
Initial $3,600 · Current $0 Reduced
29 CFR 1910.147(c)(4)(i):  Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  Specific procedural steps were not completed for equipment including but not limited to the flock line, powered with electrical and pneumatic energies.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3600

1910.303 B02

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 26, 2013
Abate by
Apr 26, 2013
Penalty
Initial $2,700 · Current $1,620 Reduced
29 CFR 1910.303(b)(2): Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling:    A jnunction box designed for permanent installation was being used as an extension cord.
Recent events (2)
  • — I (S) $1620
  • — Z (S) $2700

1910.1000 C

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Apr 26, 2013
Abate by
May 31, 2013
Penalty
Initial $2,700 · Current $0 Reduced
29 CFR 1910.1000(c): Table Z-3. An employee's exposure to any substance listed in Table Z-3, in any 8-hour work shift of a 40-hour work week, shall not exceed the 8-hour time weighted average limit given for that substance in the table:  For at least one employee in the flock department, who on 04/02/13 was exposed to 17.19 mg/m3 of inert respirable dust during the 395 minute sampling period.  Exposure calculations include a zero increment for the 85 minutes not sampled.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2700

1910.1000 E

Deleted Serious Gravity 1 1 instance 2 exposed
Issued
Apr 26, 2013
Abate by
May 31, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1000(e): To achieve compliance with paragraphs (a) through (d) of this section, administrative or engineering controls must first be determined and implemented whenever feasible. When such controls are not feasible to achieve full compliance, protective equipment or any other protective measures shall be used to keep the exposure of employees to air contaminants within the limits prescribed in this section. Any equipment and/or technical measures used for this purpose must be approved for each particular use by a competent industrial hygienist or other technically qualified person. Whenever respirators are used, their use shall comply with 1910.134:  Engineering controls were not implemented to reduce the exposure to employees as described in citation 1, item 8b  .  Engineering controls usually effective in these circumstances include but are not limited to the following:  1.  Install an automated process to return unused flock back into the overhead bin.  2.  Turn off the flocking operation when the employee enters the flock booth.     3.  Slow down the flocking operation to reduce the amount of unused flock.  Abatement Steps:  Step 1:  Submit to the Area Director a written detailed plan of abatement outlining a schedule for the implementation of engineering and/or administrative measures to control employee exposures as referenced in this citation.  This plan shall include, at a mininum, target dates for the following actions which must be consistent with the dates required by this citation.   a)  Evaluation of the extent and location of the hazard source.  b)  Evaluation of control measures.  c)  Selection of optimum control method(s).  d)  Determination of control measure design.  e)  Ordering and delivery of equipment and material(s).  f)   Installation of control measures.  g)  Training of employees in proper operation and maintenace of newly- implemented control measures.  h)  Assurance of effective performance of control measures.  All control measures shall be evaluated for each particular use by a technically qualified person.  Abatement must be completed by ***30 days***.   Step 2:  Correction should have been completed by the implementation of feasible engineering controls and/or administrative controls and their effectiveness in achieving compliance.  Abatement must be completed by  ***60 days***.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 F05 I

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 26, 2013
Abate by
May 6, 2013
Penalty
Initial $2,700 · Current $1,620 Reduced
29 CFR 1910.1200(f)(5)(i): The employer shall ensure that each container of hazardous chemicals in the work environment is identified with the hazardous chemical(s) contained therein:      A 2-liter plastic bucket containing 1 liter of n-butyl acetate was not labeled with its chemical identity.
Recent events (2)
  • — I (S) $1620
  • — Z (S) $2700

1910.1200 F05 II

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 26, 2013
Abate by
May 6, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(5)(ii): Appropriate hazard warnings, or alternatively, words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals, and which, in conjunction with the other information immediately available to employees under the hazard communication program, will provide employees with the specific information regarding the physical and health hazards of the hazardous chemical:  A 2-liter plastic container containing 1 liter of n-butyl acetate was not labeled with its hazard warnings.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.132 D02

Other-than-serious 1 instance 136 exposed
Issued
Apr 26, 2013
Abate by
May 31, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(2): The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment;  The workplace hazard assessment was not certified as being completed.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.138 B

Other-than-serious 1 instance 2 exposed
Issued
Apr 26, 2013
Abate by
May 6, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.138(b): Selection. Employers shall base the selection of the appropriate hand protection on an evaluation of the performance characteristics of the hand protection relative to the task(s) to be performed, conditions present, duration of use, and the hazards and potential hazards identified:  The employee in the flock department who handled the n-butyl acetate wore latex gloves, which are rated poor for that chemical.  Neoprene, polyvinyl alcohol or nitrile are recommended.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Mantaline Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337145981.