JACKSONVILLE, FL —
OSHA Inspection: FCB CONSTRUCTION, INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of FCB CONSTRUCTION, INC. in 4521 GREY HAWK LOT 190, JACKSONVILLE, FL 32214 (NAICS 238170). OSHA activity number 337197016.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FCB CONSTRUCTION, INC.
- Site address
- 4521 GREY HAWK LOT 190
- City
- JACKSONVILLE
- State
- FL
- ZIP
- 32214
- Mailing
- P.O. BOX 188, BOSTWICK, FL 32007
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 5
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.102 A01
- Issued
- Dec 13, 2012
- Penalty
- Initial $1,360 · Current $1,360
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a. On or about November 1, 2012, the employees using pneumatic staplers with 2-inch staplers while installing lathe for stucco preparation were not wearing eye protection, exposing themselves to eye injuries.
Recent events (1)
- — Z (S) $1360
1926.451 E01
- Issued
- Dec 13, 2012
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: a. On or about November 1, 2012, the tubular scaffold system did not have a ladder or other safe means of access, exposing employees to a fall hazard.
Recent events (1)
- — Z (S) $2000
1926.451 G01
- Issued
- Dec 13, 2012
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a. On or about November 1, 2012, the tubular framed scaffold did not have an end rail, exposing employees to a 12 feet 6-inch fall hazard.
Recent events (1)
- — Z (S) $2000
1926.501 B13
- Issued
- Dec 13, 2012
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about November 1, 2012, on the 6:12 pitch roof, employees installing stucco were not protected from a 10 feet fall hazard by the use of a fall protection system.
Recent events (1)
- — Z (S) $1600
1926.1053 B01
- Issued
- Dec 13, 2012
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladders length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. On or about November 11, 2012, the extension ladder used to access the roof did not extend 3 feet above the eave, exposing employees to a 10 feet fall hazard.
Recent events (1)
- — Z (S) $1600
More inspections at FCB Construction, INC.
View FCB Construction, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238170)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337197016.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.