CHICAGO, IL —
OSHA Inspection: JOEL KENNEDY CONSTRUCTING CORP.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JOEL KENNEDY CONSTRUCTING CORP. in N RACINE & W. NELSON, CHICAGO, IL 60657 (NAICS 237110). OSHA activity number 337224810.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JOEL KENNEDY CONSTRUCTING CORP.
- Site address
- N RACINE & W. NELSON
- City
- CHICAGO
- State
- IL
- ZIP
- 60657
- Mailing
- P.O. BOX 509, GURNEE, IL 60031
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 55
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.300 B01
- Issued
- Apr 22, 2013
- Abate by
- Apr 26, 2013
- Penalty
- Initial $3,080 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: a) Employees were using unguarded DeWalt Model# D28402 grinder while performing sewer and water work. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (3)
- — F (O) $1000
- — C (S) $3080
- — Z (S) $3080
1926.651 C02
- Issued
- Apr 22, 2013
- Penalty
- Initial $3,850 · Current $1,925 Reduced
General-duty citation text
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees: a) Employees were not provided with a safe means of egress when working in a trench with a depth of approximately 8.2 feet. No abatement certification or documentation is required for this item.
Recent events (3)
- — F (S) $1925
- — C (S) $3850
- — Z (S) $3850
1926.651 J02
- Issued
- Apr 22, 2013
- Penalty
- Initial $3,850 · Current $1,925 Reduced
General-duty citation text
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary: a) Employees were not protected from the hazard of falling or rolling excavated material that was placed and kept at the edge of the trench. No abatement certification or documentation is required for this item.
Recent events (3)
- — F (S) $1925
- — C (S) $3850
- — Z (S) $3850
1926.652 A01
- Issued
- Apr 22, 2013
- Abate by
- Apr 26, 2013
- Penalty
- Initial $61,600 · Current $29,150 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(b) or 1926.652(c): a) Employees were not protected from the hazard of cave-in while working in a trench measuring approximately 8.2 feet in depth. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
- — F (R) $29150
- — C (W) $61600
- — Z (W) $61600
1926.404 B01 II
- Issued
- Apr 22, 2013
- Abate by
- Apr 26, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(b)(1)(ii): Where an assured equipment grounding program was not utilized, receptacles were not protected with ground fault circuit interrupters when on a two-wire, single- phase portable or vehicle-mounted generator rated more than 5kW, or where the circuit conductors of the generator were not insulated from the generator frame and all other grounded surfaces: a) Employees were using three-wire 120/240 Volt, Champlion Model# 41533 Portable Generator with receptacle not protected with ground fault circuit interrupters to power tools onsite. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
More inspections at Joel Kennedy Constructing Corp.
View Joel Kennedy Constructing Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 237110)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337224810.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.