Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SPIVEY UTILITY CONSTRUCTION COMPANY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SPIVEY UTILITY CONSTRUCTION COMPANY in 5205 NEBRASKA AVENUE, TAMPA, FL 33610 (NAICS 237130). OSHA activity number 337264212.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Spivey Utility Construction Company — free Get an email when a new federal OSHA severe-injury report for Spivey Utility Construction Company is published. One employer, no account, unsubscribe in one click.
Site address
5205 NEBRASKA AVENUE
City
TAMPA
State
FL
ZIP
33610
Mailing
13338 INTERLAKEN RD, ODESSA, FL 33556
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237130
Employees
4
Ownership type
A

2 citations on file for this inspection.

1926.652 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 18, 2012
Penalty
Initial $4,500 · Current $3,375 Reduced
29 CFR 1926.652(a)(1):     Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c). The employer had not complied with the provisions of 29 CFR 1926.652(b)(1)(i) in that the:    (a) In a trench measuring 6 feet long, 2.6 feet wide and 6.8 feet deep - During the locating of utility ilnes employees were working in an unprotected excavation next to an active roadway were exposed to a caught in hazard. The soil was previously disturbed type "C" soil. A protective system (shoring, shielding or sloping) was not provided for employees. Observed on or about November 7, 2012.
Recent events (2)
  • — I (S) $3375
  • — Z (S) $4500

1926.651 C02

Repeat Gravity 5 1 instance 3 exposed
Issued
Dec 18, 2012
Penalty
Initial $9,000 · Current $6,750 Reduced
29 CFR 1926.651(c)(2):     A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:    (a) In the trench excavation - when locating utility lines employees were exposed to a cave-in hazard in that, a safe means of egress was not provided trench which was 6' feet 8" inches in depth, on or about November 7, 2012.    Spivey Utility Construction was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.651(c)(2) which was contained in OSHA inspection 314100892, citation 01, item 001 and was affirmed as a final order on 02/11/10, with respect to a workplace located at 7th Ave. & 31st St., Tampa, FL.33605.
Recent events (2)
  • — I (R) $6750
  • — Z (R) $9000

View Spivey Utility Construction Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337264212.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.