Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: L & S MAINTENANCE, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of L & S MAINTENANCE, LLC in BESIDE 106 E. WALNUT STREET, PLEASANTVILLE, OH 43148 (NAICS 238320). OSHA activity number 337272819.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch L & S Maintenance, LLC — free Get an email when a new federal OSHA severe-injury report for L & S Maintenance, LLC is published. One employer, no account, unsubscribe in one click.
Site address
BESIDE 106 E. WALNUT STREET
City
PLEASANTVILLE
State
OH
ZIP
43148
Mailing
7845 WISTERIA LANE, EVANSVILLE, IN 47720
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238320
Employees
4
Ownership type
A

7 citations on file for this inspection.

1926.150 A04

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Dec 10, 2012
Penalty
Initial $1,600 · Current $0 Reduced
29 CFR 1926.150(a)(4):     All firefighting equipment shall be periodically inspected and maintained in operating condition. Defective equipment shall be immediately replaced.    a.     On the site where a water tower was being blasted and then repainted, the fire extinguisher on site had been discharged and was empty thereby exposing employees to a fire/explosion hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1600

1926.152 F03

Serious Gravity 5 1 instance 4 exposed
Issued
Dec 10, 2012
Abate by
Dec 20, 2012
Penalty
Initial $1,600 · Current $640 Reduced
29 CFR 1926.152(f)(3):     Flammable liquids may be used only where there are no open flames or other sources of ignition within 50 feet of the operation, unless conditions warrant greater clearance.    a.     On the site where a water tower was being painted, employees were smoking in close proximity to flammables such as, but not limited to, acetone and gasoline, thereby exposing employees to a contact hazard.
Recent events (2)
  • — I (S) $640
  • — Z (S) $1600

1926.350 A10

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Dec 10, 2012
Penalty
Initial $1,600 · Current $0 Reduced
29 CFR 1926.350(a)(10):     Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour.       a.     On the site where acetalene and oxygen tanks were used over one week ago, the cylinders were stored on a cart together thereby exposing employees to a fire/exposion hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1600

1926.404 F06

Serious Gravity 5 1 instance 4 exposed
Issued
Dec 10, 2012
Penalty
Initial $1,600 · Current $640 Reduced
29 CFR 1926.404(f)(6):     Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.    a.     On the site of the water tower being painted, the extension cord used to provide power from the shelter house to the job site for powering tools and equipment, the ground prong was missing.
Recent events (2)
  • — I (S) $640
  • — Z (S) $1600

1926.405 A02 II I

Serious Gravity 5 2 instances 4 exposed
Issued
Dec 10, 2012
Penalty
Initial $1,600 · Current $0 Reduced
29 CFR 1926.405(a)(2)(ii)(I):     Flexible cords and cables shall be protected from damage. Sharp corners and projections shall be avoided. Flexible cords and cables may pass through doorways or other pinch points, if protection is provided to avoid damage.    a.     In the fenced in area where a water tower was being painted, the extension cord used to supply power to the swing stage scaffold was cut through the insulation and into the wiring thereby exposing employees to a contact hazard.    b.      On the site where a water tower was being painted, the extension cord supplying power to the swing stage moters was pinched between the door and crimped from the pressure of the door on the cord thereby exposing employees to a contact hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1600

1926.502 E07

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Dec 10, 2012
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1926.502(e)(7):     Snaphooks shall be sized to be compatible with the member to which they are connected to prevent unintentional disengagement of the snaphook by depression of the snaphook keeper by the connected member, or shall be a locking type snaphook designed and used to prevent disengagement of the snaphook by the contact of the snaphook keeper by the connected member. As of January 1, 1998, only locking type snaphooks shall be used.      a.     On the site where an employee was observed free climbing a ladder approximatily 120 feet, the snap hooks being used as part of the fall protection system were not designed form the climbing method of climbing and clipping while  climbing the ladder thereby exposing employees to a fall hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

1926.1053 A19

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Dec 10, 2012
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1926.1053(a)(19):     Where the total length of a climb equals or exceeds 24 feet (7.3 m), fixed ladders shall be equipped with one of the following:    29 CFR 1926.1053(a)(19)(i):     Ladder safety devices; or    29 CFR 1926.1053(a)(19)(ii):     Self-retracting lifelines, and rest platforms at intervals not to exceed 150 feet (45.7 m);     a.     On the site of the water tower being painted, the employer did not provide  personal protective equipment for the employee free climbing the fixed ladder over 100 feet thereby exposing the employees to a fall hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

View L & S Maintenance, LLC's full OSHA safety record →