Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ARMY CORPS OF ENGINEERS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ARMY CORPS OF ENGINEERS in THE DALLES DAM, THE DALLES, OR 97058 (NAICS 811310). OSHA activity number 337304224.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Army Corps of Engineers — free Get an email when a new federal OSHA severe-injury report for Army Corps of Engineers is published. One employer, no account, unsubscribe in one click.
Site address
THE DALLES DAM
City
THE DALLES
State
OR
ZIP
97058
Mailing
P.O. BOX 564, THE DALLES, OR 97058
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811310
Employees
121
Ownership type
D

9 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 5 instances 22 exposed
Issued
Apr 2, 2013
Abate by
Jun 27, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by:    (a) The Monarch DS&G metal lathe was not equipped with a shield to prevent injuries to employees from flying metal chips.    (b) The American Wyle Co. metal lathe was not equipped with a shield to prevent injuries to employees from flying metal chips.    (c) The red LeBlond metal lathe was not equipped with a shield to prevent injuries to employees from flying metal chips.    (d) The Dake hydraulic press has no guarding to prevent injuries to employees from flying objects.    (e) In-running nip points and rotating parts below the table of the Marvel Mark II vertical bandsaw was not fully guarded exposing employees to serious injuries.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A03 II

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 2, 2013
Abate by
Apr 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    (a) The Peck Stow, & Wilcox manually operated shears, used to cut rubber, was not equipped with a blade guard, exposing employees to amputations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.215 B09

Serious Gravity 5 1 instance 47 exposed
Issued
Apr 2, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:    (a) The Rockwell bench grinder's abrasive wheel, located in the Welding shop, was out of adjustment with the tongue guard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 C02 I

Serious Gravity 5 1 instance 47 exposed
Issued
Apr 2, 2013
Abate by
Apr 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting:  Welding shop-    (a) Employees are exposed serious injuries caused by the power transmission's rotating shaft of the Rockwell bench grinder.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 D01

Serious Gravity 5 1 instance 8 exposed
Issued
Apr 2, 2013
Abate by
Apr 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):     Resource Maintenance Area-  (a)The red cement mixer's pulley was not guarded, exposing employees to injuries of rotating parts.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.242 A

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 2, 2013
Abate by
Apr 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.242(a): Hand and portable powered tools or equipment were not kept in safe condition:     (a) The head of a chisel, located in a tool box near Main Unit #2, was mushrooming exposing employee to flying metal pieces.     (b) Hose connector fittings of air compressor lines, charged at 125 psi, were not secured with safely hardware to prevent lines from coming apart and exposing employees to serious injuries from line whipping.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.269 V04 IV

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 2, 2013
Abate by
Apr 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.269(v)(4)(iv): Entrances to rooms and spaces that are not under the observation of an attendant were not kept locked.    Power House, 4th floor-  (a) Access to rooms for terminals panels were left open and unattended to prevent unauthorized personnel from entry, exposing them to live parts with various voltages of 110 volts and greater.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.304 G05

Serious Gravity 1 1 instance 25 exposed
Issued
Apr 2, 2013
Abate by
Apr 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:    (a) The sump pump winch's 110 volt power cord was missing the ground prong, which was located on the 1st floor of the oil purifying room.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 1 2 instances 25 exposed
Issued
Apr 2, 2013
Abate by
Apr 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:    1st floor of the oil purifying room-  (a)The sump pump winch's 110 volt power cord was not connected to prevent tension from being placed on the conductors, exposing employees to electrical shock.     Power House Machine Shop-  (b) The Iron Worker "Metal Muncher" foot treadle's electrical cord was not attached to prevent strain or tension on the conductors causing the employees to be exposed to electrical shocks.       Power House 4th floor main unit 5-  (c) The portable forklift charger, SN# 7955s plug was not connected to the plug to prevent tension from being placed on the conductors, exposing employees to electrical shocks.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0