Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SCHILLER GROUNDS CARE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SCHILLER GROUNDS CARE in 1401 LOGAN STREET, NORFOLK, NE 68701 (NAICS 333112). OSHA activity number 337324016.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Schiller Grounds Care — free Get an email when a new federal OSHA severe-injury report for Schiller Grounds Care is published. One employer, no account, unsubscribe in one click.
Site address
1401 LOGAN STREET
City
NORFOLK
State
NE
ZIP
68701
Mailing
PO BOX 2401, NORFOLK, NE 68702
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333112
Employees
25
Ownership type
A

7 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 15, 2013
Abate by
Feb 2, 2013
Penalty
Initial $5,000 · Current $3,000 Reduced
29 CFR 1910.23(c)(1):     Every open-sided floor or platform 4 feet or more above adjacent floor or ground level shall be guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides except where there is entrance to a ramp, stairway, or fixed ladder. The railing shall be provided with a toeboard wherever, beneath the open sides,    The employer is failing to protect employees from potential fall hazards associated with using the unprotected space above the office area as storage.  This was most recently evident during the inspection of the facility located at 1401 Logan St. Norfolk, NE 68701, where the employer has employees exposed to a 9'6" fall hazard as they are storing the aerators they manufacture on the space above the offices and there are no forms of fall protection to prevent an employee walking up there from falling to the production floor below.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $5000

1910.107 F01

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 15, 2013
Abate by
Feb 2, 2013
Penalty
Initial $3,000 · Current $2,100 Reduced
29 CFR 1910.107(f)(1):     Sprinkler heads protecting spray paint booths shall be kept as free from deposits as practical by cleaning daily if necessary:    The employer is failing to protect employees from potential fire hazards associated with unserviceable fire sprinkler heads in the paint booth.  This was most recently evident during the inspection of the facility located at 1401 Logan St. Norfolk, NE 68701, where the employer has employees spraying paint onto components of their product using a 9x66 paint booth protected against fire hazards by a permanently installed sprinkler system where the sprinkler heads have had excessive spray build up to the extent that questions their function ability and have not been cleaned in over six months.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3000

1910.134 C02 I

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 15, 2013
Abate by
Feb 17, 2013
Penalty
Initial $3,000 · Current $2,100 Reduced
29 CFR 1910.134(c)(2)(i):     Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:    The employer is failing to protect employees from potential respiratory hazards associated with uninformed employees voluntarily using respirators.  This was most recently evident during the inspection of the facility located at 1401 Logan St. Norfolk, NE 68701, where the employer has employees who voluntarily use respirators in the powder coat operation but have not been briefed in accordance with the standard in this subpart.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3000

1910.134 C02 II

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 15, 2013
Abate by
Feb 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(ii):     The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user:(a) (LOCATION) (IDENTIFY SPECIFIC OPERATION/CONDITION) (DESCRIBE HAZARD)    The employer is failing to protect employees from potential respiratory hazards associated with employees voluntarily using respirators and the employers lack of a written respiratory program that addresses the methods for which the voluntary use will exist.  This was most recently evident during the inspection of the facility located at 1401 Logan St. Norfolk, NE 68701, where the employer has employees who voluntarily use respirators in the powder coat operation without having developed a written program to outline the parameters of the respirators use.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C06 I

Serious Gravity 1 1 instance 3 exposed
Issued
Jan 15, 2013
Abate by
Feb 17, 2013
Penalty
Initial $3,000 · Current $2,100 Reduced
29 CFR 1910.147(c)(6)(i):     The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    The employer is failing to protect employees from potential electrical and caught between hazards associated with employees locking out equipment using written specific procedures that have not been reviewed and certified within the past year.  This was most recently evident during the inspection of the facility located at 1401 Logan St. Norfolk, NE 68701, where the employer has maintenance employees who conduct lockout and tag out on the companys equipment using written specific procedures developed by the company and have not been reviewed in over a year.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3000

1910.178 F02

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 15, 2013
Abate by
Feb 2, 2013
Penalty
Initial $3,000 · Current $2,100 Reduced
29 CFR 1910.178(f)(2):     The storage and handling of liquefied petroleum gas fuel shall be in accordance with NFPA Storage and Handling of Liquefied Petroleum Gases (NFPA No. 58-1969), which is incorporated by reference as specified in Sec. 1910.6.    The employer is failing to protect employees from potential explosion hazards associated with the improper storage of liquid petroleum gas (propane) tanks.  This was most recently evident during the inspection of the facility located at 1401 Logan St. Norfolk, NE 68701, where the employer is storing four propane tanks inside the building, directly next to the loading dock door where they have employees operating Caterpillar forklifts used to load product on to delivery trucks.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3000

1910.303 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 15, 2013
Abate by
Feb 2, 2013
Penalty
Initial $5,000 · Current $3,500 Reduced
29 CFR 1910.303(b)(2):     Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:(a) (LOCATION) (IDENTIFY EQUIPMENT) (STATE HAZARD(S) TO EMPLOYEE(S))    The employer is failing to protect employees from potential electrical hazards associated with the improper use of electrical components.  This was most recently evident during the inspection of the facility located at 1401 Logan St. Norfolk, NE 68701, where the employer has employees using the microwave and small refrigerator receiving 110v power through an electrical box originally designed for permanent wall mounting; the employer has fabricated it as a substitute for a portable power tap for which it was not designed to be used and creates potential electrical shock hazards as it is left unsecured on the table.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $5000

View Schiller Grounds Care's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337324016.