BUFFALO, NY —
OSHA Inspection: COMMITMENT 2000 INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of COMMITMENT 2000 INC in 105 MONSIGNOR VALENTE DRIVE, BUFFALO, NY 14206 (NAICS 311812). OSHA activity number 337349815.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COMMITMENT 2000 INC
- Site address
- 105 MONSIGNOR VALENTE DRIVE
- City
- BUFFALO
- State
- NY
- ZIP
- 14206
- Mailing
- 105 MONSIGNOR VALENTE DRIVE, BUFFALO, NY 14206
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311812
- Employees
- 45
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.37 A03
- Issued
- Jan 11, 2013
- Abate by
- Feb 15, 2013
- Penalty
- Initial $1,785 · Current $1,339 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: a) On or about 11/14/12, in the forklift traffic area wall markings 28 and 29, an exit route/door access was blocked by a Wright Self Dumping Hopper. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1338.75
- — Z (S) $1785
1910.147 C01
- Issued
- Jan 11, 2013
- Abate by
- Feb 15, 2013
- Penalty
- Initial $2,975 · Current $2,231 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) On or about 11/14/12, in the establishment, employees are involved in servicing and maintaining equipment, such as, but not limited to: repairing a I.J. Whithe Cooler Conveyor's chain, changing a Press belt and cleaning a T-line Mixer, without using an energy control program, machine-specific/group lockout-tagout procedures, hardware, training or periodic inspections. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2231.25
- — Z (S) $2975
1910.151 C
- Issued
- Jan 11, 2013
- Abate by
- Feb 15, 2013
- Penalty
- Initial $2,380 · Current $1,785 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a) On or about 11/14/12, in the chemical room, there was not an Emergency Eye wash immediately available for sanitation employees handling and transferring corrosive chemicals such as, but not limited to: PE-12, Heavy Duty Commercial Cleaner and Sanitime. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1785
- — Z (S) $2380
1910.212 A03 II
- Issued
- Jan 11, 2013
- Penalty
- Initial $2,380 · Current $1,785 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle: a) On or about 11/14/12, in the A-Line production areas, an Empire Mixer had an inadequate guard with openings of approximately 4 inches exposing employees' hands/fingers to be in contact with mixer's agitator. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1785
- — Z (S) $2380
1910.303 G01
- Issued
- Jan 11, 2013
- Abate by
- Feb 15, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: a) On or about 11/04/12, in the production areas, electrical panels and a disconnect switch access were blocked by a yellow plastic container, Igloo water container and a garbage container. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Commitment 2000 INC
View Commitment 2000 INC's full OSHA safety record →
More inspections in this industry (NAICS 311812)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337349815.