Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MARINE SYSTEMS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MARINE SYSTEMS, INC. in 30 LONGHILL ROAD, SOUTHWEST HARBOR, ME 04679 (NAICS 336612). OSHA activity number 337378426.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Marine Systems, INC. — free Get an email when a new federal OSHA severe-injury report for Marine Systems, INC. is published. One employer, no account, unsubscribe in one click.
Site address
30 LONGHILL ROAD
City
SOUTHWEST HARBOR
State
ME
ZIP
04679
Mailing
P.O. BOX 1512, SOUTHWEST HARBOR, ME 04679
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336612
Employees
1
Ownership type
A

2 citations on file for this inspection.

1910.212 A01

Serious Gravity 1 1 instance 1 exposed
Issued
Nov 26, 2012
Abate by
Dec 2, 2012
Penalty
Initial $1,020 · Current $663 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:      Boat Shop - The Delta drill press did not have a guard for the rotating chuck and drill bit.
Recent events (2)
  • — I (S) $663
  • — Z (S) $1020

1910.23 C01

Other-than-serious 1 instance 1 exposed
Issued
Nov 26, 2012
Abate by
Dec 2, 2012
Penalty
Initial $1,020 · Current $0 Reduced
29 CFR 1910.23(c)(1): Every open-sided floor or platform 4 feet or more above adjacent floor or ground level shall be guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides except where there is entrance to a ramp, stairway, or fixed ladder:      Boat Shop - The upper cat walk had an unguarded opening approximately 11 feet long with a fall of 7 feet to the lower floor.
Recent events (2)
  • — I (O) $0
  • — Z (S) $1020

View Marine Systems, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337378426.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.