Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CELLOFOAM NORTH AMERICA INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CELLOFOAM NORTH AMERICA INC. in 1961 ROCKDALE INDUSTRIAL BLVD., CONYERS, GA 30012 (NAICS 326140). OSHA activity number 337479018.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cellofoam North America INC. — free Get an email when a new federal OSHA severe-injury report for Cellofoam North America INC. is published. One employer, no account, unsubscribe in one click.
Site address
1961 ROCKDALE INDUSTRIAL BLVD.
City
CONYERS
State
GA
ZIP
30012
Mailing
1917 ROCKDALE INDUSTRIAL BLVD., CONYERS, GA 30012
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326140
Employees
75
Ownership type
A

9 citations on file for this inspection.

1910.36 E01

Serious Gravity 5 1 instance 10 exposed
Issued
Mar 6, 2013
Abate by
Apr 1, 2013
Penalty
Initial $6,600 · Current $3,960 Reduced
29 CFR 1910.36(e)(1): A side-hinged door was not used to connect to an exit route.    On or about November 20, 2012, employees were exposed to fire hazards when the exit door in the expansion room was a rollup door with a screen door behind the rollup door.
Recent events (2)
  • — I (S) $3960
  • — Z (S) $6600

1910.37 A03

Serious Gravity 5 1 instance 10 exposed
Issued
Mar 6, 2013
Abate by
Apr 1, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:    On or about November 20, 2012, employees were exposed to fire hazards when the exit door in the maintenance department had a bar placed across it to discourage employees from using the door when entering the building and the bar was not removed during the day when the building was occupied.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 Q07

Serious Gravity 5 1 instance 10 exposed
Issued
Mar 6, 2013
Abate by
Mar 12, 2013
Penalty
Initial $5,500 · Current $3,300 Reduced
29 CFR 1910.178(q)(7): Powered industrial truck(s) which were used on a round-the-clock basis were not examined for defects after each shift:    On or about November 20, 2012, employees were exposed to struck-by hazards when the forklifts were not inspected on a daily basis.
Recent events (2)
  • — I (S) $3300
  • — Z (S) $5500

1910.252 B02 III

Serious Gravity 1 1 instance 5 exposed
Issued
Mar 6, 2013
Abate by
Mar 12, 2013
Penalty
Initial $3,300 · Current $1,980 Reduced
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields:    On or about November 20, 2012, employees were exposed to weld flash hazards when the welding done in the roto area was done without welding screens to protect employees working in the adjacent areas or passing near the area to exit the building.
Recent events (2)
  • — I (S) $1980
  • — Z (S) $3300

1910.303 B01 IV

Serious Gravity 5 2 instances 5 exposed
Issued
Mar 6, 2013
Penalty
Initial $3,740 · Current $2,244 Reduced
29 CFR 1910.303(b)(1)(iv): Electrical insulation was not free from recognized hazards that were likely to cause death or serious physical harm to employees:    On or about November 20, 2012, employees were exposed to electrical hazards when reeled extension cords in the maintenance department were damaged and patched with tape.
Recent events (2)
  • — I (S) $2244
  • — Z (S) $3740

1910.305 G01 IV A

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 6, 2013
Abate by
Apr 1, 2013
Penalty
Initial $4,400 · Current $2,640 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:    On or about November 20, 2012, employees were exposed to electrical hazards for approximately two years when temporary flexible cords in the expansion room had not been replaced with fixed wiring when the equipment was permanently located.
Recent events (2)
  • — I (S) $2640
  • — Z (S) $4400

1910.178 L01 I

Other-than-serious 1 instance 10 exposed
Issued
Mar 6, 2013
Abate by
Apr 1, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(1)(i):     The employer shall ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    On or about November 20, 2012, employees were exposed to struck-by hazards when new employees had not been evaluated.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.178 L06

Other-than-serious 1 instance 10 exposed
Issued
Mar 6, 2013
Abate by
Apr 1, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(6): The certification did not include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation:    On or about November 20, 2012, employees were exposed to struck-by hazards when employee training, evaluations, and certification did not include the date when the actual evaluation took place.  Documentation has the date that employees reviewed the videos, not the actual date that the employee was evaluated.  Some employees are permitted to drive forklifts without having been evaluated by the employer.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 G01

Deleted Other-than-serious 1 instance 5 exposed
Issued
Mar 6, 2013
Abate by
Apr 1, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(1): The employer did not have a material safety data sheet for each hazardous chemical in use:    On or about November 20, 2012, employees were exposed to chemical hazards when the employer did not have a safety data sheet for each chemical in use.  Employees were exposed to chemicals such as, but not limited to, propane, acetylene, oxygen, machine coolant, and maintenance oil and grease.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Cellofoam North America INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337479018.