Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CELLOFOAM NORTH AMERICA, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CELLOFOAM NORTH AMERICA, INC. in 400 E. HOUSER AVENUE, SALLISAW, OK 74955 (NAICS 326140). OSHA activity number 341328276.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cellofoam North America, INC. — free Get an email when a new federal OSHA severe-injury report for Cellofoam North America, INC. is published. One employer, no account, unsubscribe in one click.
Site address
400 E. HOUSER AVENUE
City
SALLISAW
State
OK
ZIP
74955
Mailing
400 E. HOUSER AVENUE, SALLISAW, OK 74955
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326140
Employees
26
Ownership type
A

3 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 25 exposed
Issued
Aug 24, 2016
Abate by
Sep 9, 2016
Penalty
Initial $6,236 · Current $3,742 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that, employees were exposed to fire hazards and/or explosion hazards caused by the presence of combustible dust.  On or about March 18, 2016, and times prior thereto, the employer did not ensure regular cleaning frequencies was established for walls, floors, and horizontal surfaces to minimize combustible dust accumulation within the Powder Mill operating area.
Recent events (2)
  • — I (S) $3741.6
  • — Z (S) $6236

1910.134 C02 I

Other-than-serious 1 instance 18 exposed
Issued
Aug 24, 2016
Abate by
Sep 16, 2016
Penalty
Initial $700 · Current $420 Reduced
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible.  On or about March 18, 2016, and times prior thereto, the employer allowed voluntary use of respirators by employees; however, the employer had not provided the information contained in Appendix D to the employees.  This exposed employees to hazards associated with improper use of the respirator.
Recent events (2)
  • — I (O) $420
  • — Z (O) $700

1910.134 C02 II

Other-than-serious 1 instance 18 exposed
Issued
Aug 24, 2016
Abate by
Oct 7, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user.  On or about March 18, 2016, and times prior thereto, the employer did not ensure employees voluntarily using respirators had been medically evaluated, or had been trained to maintain the respirators.  This exposed employees to hazards associated with respiratory-related illnesses.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Cellofoam North America, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341328276.