WASHINGTON, DC —
OSHA Inspection: NATIONAL ROOFING
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of NATIONAL ROOFING in 5050 MACAURTHER BLVD, WASHINGTON, DC 20036 (NAICS 236116). OSHA activity number 337530414.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NATIONAL ROOFING
- Site address
- 5050 MACAURTHER BLVD
- City
- WASHINGTON
- State
- DC
- ZIP
- 20036
- Mailing
- 1629 K ST NW, WASHINGTON, DC 20036
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236116
- Employees
- 11
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Mar 7, 2013
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: a) On or about October 25, 2012, front roof area, employees working on a 10 in 12 pitch roof did not have a personal fall arrest system to protect them from a 25-30 foot fall to ground level. No abatement certification or documentation required.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1926.1053 B01
- Issued
- Mar 7, 2013
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. a) On or about October 25, 2012, front of home, employees were accessing an extension ladder that was extended 24 inches above the platform/roof. No abatement certification or documentation required.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
More inspections at National Roofing
View National Roofing's full OSHA safety record →
More inspections in this industry (NAICS 236116)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337530414.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.