Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RL UTILITIES

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RL UTILITIES in 11810 FAIRMONT PARKWAY, LA PORTE, TX 77571 (NAICS 237110). OSHA activity number 337532212.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch RL Utilities — free Get an email when a new federal OSHA severe-injury report for RL Utilities is published. One employer, no account, unsubscribe in one click.
Establishment
RL UTILITIES
Site address
11810 FAIRMONT PARKWAY
City
LA PORTE
State
TX
ZIP
77571
Mailing
3900 UNDERWOOD, LA PORTE, TX 77572
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
6
Ownership type
A

3 citations on file for this inspection.

1926.651 C02

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 5, 2013
Abate by
Feb 7, 2013
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.651(c)(2):  A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:    a)  At the worksite, 11810 Fairmont Parkway, La Porte, Texas, on November 26, 2012, an employee was inside the 12 foot 6 inch deep excavation without any form of egress.  This condition exposed the employee to cave-in hazards.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1926.651 J02

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 5, 2013
Abate by
Feb 7, 2013
Penalty
Initial $2,400 · Current $1,440 Reduced
29 CFR 1926.651(j)(2):  Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary:      a)  At the worksite, at 11810 Fairmont Parkway, La Porte, TX, on November 26, 2012, an employee was working inside the 12 foot 6 inch deep excavation.  The spoil piles were located adjacent to the sidewall of the excavation.  This condition exposed the employee to falling debris and rock.
Recent events (2)
  • — I (S) $1440
  • — Z (S) $2400

1926.652 B

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 5, 2013
Abate by
Feb 7, 2013
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.652(b): The slopes and configurations of sloping and benching systems were not in accordance with the requirement options of 29 CFR 1926.652(b)(1), (b)(2), (b)(3), or (b)(4):    a)  At the worksite, at 11810 Fairmont Parkway, La Porte, TX, on November 26, an employee was inside the 12 foot  6 inch deep excavation preparing to install piping.  The foreman designed a bench system which had 4 benches measuring approximatley 3 to 4 feet tall by 1 to 2 feet wide.  The employee was not protected against cave-ins.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

View RL Utilities's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337532212.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.