HOUSTON, TX —
OSHA Inspection: RL UTILITIES
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of RL UTILITIES in 1414 WOOD HOLLOW DR., HOUSTON, TX 77027 (NAICS 237110). OSHA activity number 342031598.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RL UTILITIES
- Site address
- 1414 WOOD HOLLOW DR.
- City
- HOUSTON
- State
- TX
- ZIP
- 77027
- Mailing
- PO BOX 1154, LA PORTE, TX 77572
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.651 K01
- Issued
- May 30, 2017
- Abate by
- Jun 5, 2017
- Penalty
- Initial $3,803 · Current $3,803
General-duty citation text
29 CFR 1926.651(k)(1): An inspection of the excavations, the adjacent areas, and protective systems was not conducted by the competent person prior to the start of work and as needed throughout the shift: a) at the construction site, where the designated competent person responsible for daily inspections of the excavation was not competent in that he was not capable of identifying existing and predictable hazards in the surroundings and working conditions which were hazardous and dangerous to employees. The designated competent person was not capable of typing soil, nor was he capable of designing a protective system in accordance with 1926 Subpart P.
Recent events (1)
- — Z (S) $3803
1926.652 A01
- Issued
- May 30, 2017
- Abate by
- Jun 5, 2017
- Penalty
- Initial $3,803 · Current $3,803
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c): a) at the construction site, where employees in an excavation, approximately 10 feet deep, were not protected from cave-ins by an adequate protective system.
Recent events (1)
- — Z (S) $3803
More inspections at RL Utilities
View RL Utilities's full OSHA safety record →
More inspections in this industry (NAICS 237110)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342031598.