BLANDON, PA ·
OSHA Inspection: TEMPLE ALUMINUM FOUNDRY, INCORPORATED
Follow-up inspection · Health discipline
At a glance
On , OSHA opened a follow-up health inspection of TEMPLE ALUMINUM FOUNDRY, INCORPORATED in 1145 PARK ROAD, BLANDON, PA 19510 (NAICS 331524). OSHA activity number 337580815.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TEMPLE ALUMINUM FOUNDRY, INCORPORATED
- Site address
- 1145 PARK ROAD
- City
- BLANDON
- State
- PA
- ZIP
- 19510
- Mailing
- 1145 PARK ROAD, BLANDON, PA 19510
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331524
- Employees
- 25
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.95 G08 II
- Issued
- Feb 5, 2013
- Abate by
- Mar 10, 2013
- Penalty
- Initial $1,020 · Current $765 Reduced
8111
General-duty citation text
29 CFR 1910.95(g)(8)(ii): When a physician did not determine that the standard threshold shift (STS) was not work related or aggravated by occupational noise exposure, the employer did not ensure that the steps described in paragraphs (A) through (D) were taken when a standard threshold shift occured: (a) Temple Aluminum Foundry, Incorporated - The employer did not take action as required in parapgraphs (B) through (D) when the Finishing Foreman was found to have an STS during the May 30, 2012 audiometric test, on or about December 12, 2012. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- · I (S) $765
- · Z (S) $1020
1910.95 D01
- Issued
- Feb 5, 2013
- Abate by
- Mar 10, 2013
- Penalty
- Initial $0 · Current $0
8111
General-duty citation text
29 CFR 1910.95(d)(1): When information indicated that any employee's exposure may equal or exceed an 8-hour time-weighted average of 85 decibels, the employer did not develop and implement a monitoring program: (a) Temple Aluminum Foundry, Incorporated - The employer did not develop or implement a monitoring program for the employees of the foundry, on or about December 12, 2012. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Temple Aluminum Foundry, Incorporated