EAST SYRACUSE, NY —
OSHA Inspection: EAGLE METALCRAFT, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of EAGLE METALCRAFT, INC. in 3550 BURNET AVE., EAST SYRACUSE, NY 13057 (NAICS 332322). OSHA activity number 337663611.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EAGLE METALCRAFT, INC.
- Site address
- 3550 BURNET AVE.
- City
- EAST SYRACUSE
- State
- NY
- ZIP
- 13057
- Mailing
- 3550 BURNET AVE., EAST SYRACUSE, NY 13057
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332322
- Employees
- 20
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.212 A01
- Issued
- Jan 10, 2013
- Abate by
- Feb 14, 2013
- Penalty
- Initial $1,500 · Current $1,050 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by rotating parts: a) Sheet Metal Dept., on or about 12/4/12: Rotating chucks on three Bridgeport milling machines were not guarded. b) Machine Shop, on or about 12/4/12: Rotating spindle ends and nut projections on a Baldor grinder next to the Matsuura Vertical Milling machine M5 and a Baldor grinder next to the Matsuura Vertical Milling machine M4 were not guarded. c) Machine Shop, on or about 12/4/12: Rotating chucks on multi head drill press attachments for four Wilton drill presses and one Delta drill press were not guarded and rotating chucks on two Bridgeport milling machines, a Clausing single head drill press and on two single head drill presses attached to a work bench identified as an 8 inch drill press and a Delta drill press were not guarded. d) Area outside the Plating Room, on or about 12/4/12: Rotating spindle end and nut projection on a belt sander was not adequately guarded on the right side. e) Timesaver Area, on or about 12/4/12: Rotating chuck on a multi head drill press attachment for the Walker Turner drill press was not guarded. Abatement certification must be submitted for these items.
Recent events (2)
- — I (S) $1050
- — Z (S) $1500
1910.242 B
- Issued
- Jan 10, 2013
- Abate by
- Jan 22, 2013
- Penalty
- Initial $900 · Current $630 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) Machine Shop, on or about 12/4/12: Compressed air gun at the Matsuura VMC #M2 measured 80 psi. b) Timesaver Area, on or about 12/4/12: Compressed air gun at the Timesaver machine measured 80 psi. Abatement certification must be submitted for instance b.
Recent events (2)
- — I (S) $630
- — Z (S) $900
1910.303 B02
- Issued
- Jan 10, 2013
- Abate by
- Feb 14, 2013
- Penalty
- Initial $900 · Current $630 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Machine Shop, on or about 12/4/12: A strip outlet attached to a workbench next to the Matsuura VMC #M2, providing current to two drill presses was not being used in accordance with the listing or labeling. b) Turning/Sawing Area, on or about 12/4/12: A strip outlet attached to the leg of a workbench, providing current to a space heater and a light was not being used in accordance with the listing or labeling. Abatement certification must be submitted for these items.
Recent events (2)
- — I (S) $630
- — Z (S) $900
1910.305 G01 IV A
- Issued
- Jan 10, 2013
- Abate by
- Feb 14, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Machine Shop, on or about 12/4/12: An orange extension cord providing current to a Baldor grinder at the Matsuura turning center #M7 was strung along the floor and being used as permanent wiring. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Eagle Metalcraft, INC.