Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: EAGLE METALCRAFT, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of EAGLE METALCRAFT, INC. in 3550 BURNET AVE., EAST SYRACUSE, NY 13057 (NAICS 332322). OSHA activity number 337663611.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Eagle Metalcraft, INC. — free Get an email when a new federal OSHA severe-injury report for Eagle Metalcraft, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3550 BURNET AVE.
City
EAST SYRACUSE
State
NY
ZIP
13057
Mailing
3550 BURNET AVE., EAST SYRACUSE, NY 13057
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
20
Ownership type
A

4 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 16 instances 8 exposed
Issued
Jan 10, 2013
Abate by
Feb 14, 2013
Penalty
Initial $1,500 · Current $1,050 Reduced
29 CFR 1910.212(a)(1):     Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by rotating parts:    a)  Sheet Metal Dept., on or about 12/4/12:  Rotating chucks on three Bridgeport milling machines were not guarded.    b)  Machine Shop, on or about 12/4/12:  Rotating spindle ends and nut projections on a Baldor grinder next to the Matsuura Vertical Milling machine M5  and a Baldor grinder next to the Matsuura Vertical Milling machine M4 were not guarded.    c)  Machine Shop, on or about 12/4/12:  Rotating chucks on multi head drill press attachments for four Wilton drill presses and one Delta drill press were not guarded and rotating chucks on two Bridgeport milling machines, a Clausing single head drill press and on two single head drill presses attached to a work bench identified as an 8 inch drill press and a Delta drill press were not guarded.    d)  Area outside the Plating Room, on or about 12/4/12:  Rotating spindle end and nut projection on a belt sander was not adequately guarded on the right side.    e)  Timesaver Area, on or about 12/4/12:  Rotating chuck on a multi head drill press attachment for the Walker Turner drill press was not guarded.    Abatement certification must be submitted for these items.
Recent events (2)
  • — I (S) $1050
  • — Z (S) $1500

1910.242 B

Serious Gravity 1 2 instances 2 exposed
Issued
Jan 10, 2013
Abate by
Jan 22, 2013
Penalty
Initial $900 · Current $630 Reduced
29 CFR 1910.242(b):     Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:      a)  Machine Shop, on or about 12/4/12:  Compressed air gun at the Matsuura VMC #M2 measured 80 psi.    b)  Timesaver Area, on or about 12/4/12:  Compressed air gun at the Timesaver machine measured 80 psi.    Abatement certification must be submitted for instance b.
Recent events (2)
  • — I (S) $630
  • — Z (S) $900

1910.303 B02

Serious Gravity 1 2 instances 2 exposed
Issued
Jan 10, 2013
Abate by
Feb 14, 2013
Penalty
Initial $900 · Current $630 Reduced
29 CFR 1910.303(b)(2):     Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    a)  Machine Shop, on or about 12/4/12:  A strip outlet attached to a workbench next to the Matsuura VMC #M2, providing current to two drill presses was not being used in accordance with the listing or labeling.    b)  Turning/Sawing Area, on or about 12/4/12:  A strip outlet attached to the leg of a workbench, providing current to a space heater and a light was not being used in accordance with the listing or labeling.    Abatement certification must be submitted for these items.
Recent events (2)
  • — I (S) $630
  • — Z (S) $900

1910.305 G01 IV A

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 10, 2013
Abate by
Feb 14, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A):     Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:    a)  Machine Shop, on or about 12/4/12:  An orange extension cord providing current to a Baldor grinder at the Matsuura turning center #M7 was strung along the floor and being used as permanent wiring.    Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Eagle Metalcraft, INC.'s full OSHA safety record →