Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NEW TECH ROOFING & PAINTING, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of NEW TECH ROOFING & PAINTING, INC. in 7821/7817 ABERDEEN LAKES DRIVE, BOYNTON BEACH, FL 33472 (NAICS 238160). OSHA activity number 337665210.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch NEW Tech Roofing & Painting, INC. — free Get an email when a new federal OSHA severe-injury report for NEW Tech Roofing & Painting, INC. is published. One employer, no account, unsubscribe in one click.
Site address
7821/7817 ABERDEEN LAKES DRIVE
City
BOYNTON BEACH
State
FL
ZIP
33472
Mailing
8422 N LAKE FOREST DRIVE, DAVIE, FL 33328
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
12
Ownership type
A

4 citations on file for this inspection.

1926.501 B11

Serious Gravity 5 3 instances 10 exposed
Issued
Mar 7, 2013
Penalty
Initial $2,400 · Current $1,200 Reduced
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems:    a) On or about 11/27/2012 at 7817/7821 Aberdeen Lakes Drive, Boynton Beach, Florida, employees were observed installing/removing roofing material from a steep slope roof without the use of conventional fall protection.    b)  On or about 11/27/2012 at 8935/8939 Rockford Road, Boynton Beach, Florida, employees were observed installing/removing roofing material from a steep slope roof without the use of conventional fall protection.    c)  On or about 11/27/2012 at 7761/7765 Rockford Road, Boynton Beach, Florida, employees were observed installing/removing roofing material from a steep slope roof without the use of conventional fall protection.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2400

1926.502 D15

Serious Gravity 5 3 instances 10 exposed
Issued
Mar 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person:    a) On or about 11/27/2012 at 7817/7821 Aberdeen Lakes Drive, Boynton Beach, Florida, employees were observed installing/removing roofing material from a steep slope roof, for which the anchorage points for the fall arrest system, was not capable of supporting at least 5,000 pounds.    b)  On or about 11/27/2012 at 8935/8939 Rockford Road, Boynton Beach, Florida, employees were observed installing/removing roofing material from a steep slope roof, for which the anchorage points for the fall arrest system, was not capable of supporting at least 5,000 pounds.      c)  On or about 11/27/2012 at 7761/7765 Rockford Road, Boynton Beach, Florida, employees were observed installing/removing roofing material from a steep slope roof, for which the anchorage points for the fall arrest system, was not capable of supporting at least 5,000 pounds.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.502 D21

Other-than-serious 3 instances 10 exposed
Issued
Mar 7, 2013
Abate by
Apr 9, 2013
Penalty
Initial $400 · Current $200 Reduced
29 CFR 1926.502(d)(21): Personal fall arrest systems were not inspected prior to each use for wear, damage, and other deterioration, and/or defective components were not removed from service:    a) On or about 11/27/2012 at 7817/7821 Aberdeen Lakes Drive, Boynton Beach, Florida, employees were were/had been wearing personal fall arrest systems while working from a rooftop, for which the employees had not inspected the systems prior to each use for wear, damage and other deterioration and defective components.    b)  On or about 11/27/2012 at 8935/8939 Rockford Road, Boynton Beach, Florida, employees were were/had been wearing personal fall arrest systems while working from a rooftop, for which the employees had not inspected the systems prior to each use for wear, damage and other deterioration and defective components.    c)  On or about 11/27/2012 at 7761/7765 Rockford Road, Boynton Beach, Florida, employees were were/had been wearing personal fall arrest systems while working from a rooftop, for which the employees had not inspected the systems prior to each use for wear, damage and other deterioration and defective components.
Recent events (2)
  • — I (O) $200
  • — Z (O) $400

1926.503 A02 II

Other-than-serious 3 instances 10 exposed
Issued
Mar 7, 2013
Abate by
Apr 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(2)(ii): The employer did not assure that each employee, as necessary, had been trained by a competent person in the correct procedures for erecting, maintaining, disassembling and inspecting the fall protection systems to be used:    a) On or about 11/27/2012 at 7817/7821 Aberdeen Lakes Drive, Boynton Beach, Florida, employees were /had been wearing personal fall arrest systems while working from a rooftop, for which the employer had not provided the employees with training on the care, use, and maintenance of the conventional (harness/rope-grab, life-line and anchor), fall protection system.     b)  On or about 11/27/2012 at 8935/8939 Rockford Road, Boynton Beach, Florida, employees were /had been wearing personal fall arrest systems while working from a rooftop, for which the employer had not provided the employees with training on the care, use, and maintenance of the conventional (harness/rope-grab, life-line and anchor), fall protection system.     c)  On or about 11/27/2012 at 7761/7765 Rockford Road, Boynton Beach, Florida, employees were /had been wearing personal fall arrest systems while working from a rooftop, for which the employer had not provided the employees with training on the care, use, and maintenance of the conventional (harness/rope-grab, life-line and anchor), fall protection system.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View NEW Tech Roofing & Painting, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337665210.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.