Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NCL GRAPHIC SPECIALTIES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NCL GRAPHIC SPECIALTIES, INC. in N29 W22960 MARJEAN LANE, WAUKESHA, WI 53186 (NAICS 323110). OSHA activity number 337733620.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch NCL Graphic Specialties, INC. — free Get an email when a new federal OSHA severe-injury report for NCL Graphic Specialties, INC. is published. One employer, no account, unsubscribe in one click.
Site address
N29 W22960 MARJEAN LANE
City
WAUKESHA
State
WI
ZIP
53186
Mailing
N29 W22960 MARJEAN LANE, WAUKESHA, WI 53186
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323110
Employees
125
Ownership type
A

5 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 10 1 instance 5 exposed
Issued
Apr 18, 2013
Abate by
Jul 15, 2013
Penalty
Initial $6,300 · Current $4,725 Reduced
29 CFR 1910.212(a)(3)(ii):     Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle:    (a)    Instance (a) deleted per informal conference.    (b)   The employer did not ensure that each employee working on the Die Cutter #1 (PMC Die Cutting Machine Series FMA 73 Serial FMA 873)  was protected from amputation hazards in that two employees worked at the machine with only one employee being protected by the use of a two hand control.    (c)    The employer did not ensure that each employee working on the Die Cutter #2 (PMC Die Cutting Machine, Series B, Serial #AB40) was protected from amputation hazards in that two employees worked at the machine with only one employee being protected by the use of a two hand control.    (d)   The employer did not ensure that each employee working on the Die Cutter #3 (PMC Die Cutting Machine, Model #L, Serial #L-1381) was protected from amputation hazards in that two employees worked at the machine with only one employee being protected by the use of a two hand control.
Recent events (2)
  • — I (S) $4725
  • — Z (S) $6300

1910.212 A01

Other-than-serious 1 instance 10 exposed
Issued
Apr 18, 2013
Abate by
Jun 5, 2013
Penalty
Initial $2,700 · Current $0 Reduced
29 CFR 1910.212(a)(1):     Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by:     (a) The clamps that hold down the paper before being cut are not guarded properly as employees have been getting their fingers crushed by the clamp.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2700

1910.303 B02

Other-than-serious 1 instance 3 exposed
Issued
Apr 18, 2013
Abate by
May 14, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2):     Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    (a) In the maintenance shop area there was a metal junction box being used as a permanent extension cord, that type of junction box is meant to be mounted. A possible Shock hazard exists.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G01 II L

Other-than-serious 1 instance 10 exposed
Issued
Apr 18, 2013
Abate by
May 14, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(ii)(L):     Temporary wiring as permitted in paragraph (a)(2) of this section.    (a) Temporary wiring was being used as permanent wiring to power the water purifyer in the pre-press room. This exposes employees to possible shock and fire hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G02 III

Other-than-serious 1 instance 1 exposed
Issued
Apr 18, 2013
Abate by
May 14, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii):     Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:    (a) A drop down plug had its outer sheath pulled away due to lack of strain relief. This exposes any employee using it to shock hazards and also all employees to fire hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View NCL Graphic Specialties, INC.'s full OSHA safety record →