OSHA Inspection: BONNEVILLE POWER ADMINISTRATION

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of BONNEVILLE POWER ADMINISTRATION in 1140 HIGHWAY 603, CHEHALIS, WA 98532 (NAICS 221122). OSHA activity number 337755615.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bonneville Power Administration — free Get an email when a new federal OSHA severe-injury report for Bonneville Power Administration is published. One employer, no account, unsubscribe in one click.
Site address
1140 HIGHWAY 603
City
CHEHALIS
State
WA
ZIP
98532
Mailing
5240 TROSPER ROAD, OLYMPIA, WA 98512
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221122
Employees
8
Ownership type
D

3 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 8, 2013
Abate by
Apr 3, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(1):     One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    A)     In the tower shop, the  lathe did not have a chuck guard.
Recent events (1)
  • — Z (S) $0

1910.305 G01 IV A

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 8, 2013
Abate by
Apr 3, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A):     Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  A)     In the power house at the Chehalis substation, a permanent 20 amp double outlet was permanently wired to the wall, and was connected to the the building electrical system by a three prong electrical cord, that was plugged into a standard 15 amp outlet in the wall.
Recent events (1)
  • — Z (S) $0

1910.1200 F05

Other-than-serious 1 instance 2 exposed
Issued
Mar 8, 2013
Abate by
Apr 3, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(5):     The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged, or marked with the identity and appropriate hazard warnings regarding the chemicals contained therein:    A) In the tower room of the facility, employees were using a container of solution that was not labeled as to its contents.  The employer was not sure what chemical was in the bottle.
Recent events (1)
  • — Z (O) $0

View Bonneville Power Administration's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337755615.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.