WAYNESBORO, PA —
OSHA Inspection: D.L. GEORGE & SONS CONSTRUCTION CO
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of D.L. GEORGE & SONS CONSTRUCTION CO in 99 CEMETERY AVENUE, WAYNESBORO, PA 17268 (NAICS 237110). OSHA activity number 337781215.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- D.L. GEORGE & SONS CONSTRUCTION CO
- Site address
- 99 CEMETERY AVENUE
- City
- WAYNESBORO
- State
- PA
- ZIP
- 17268
- Mailing
- 20 EAST SIXTH STREET, WAYNESBORO, PA 17268
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 3
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.651 J02
- Issued
- Jan 14, 2013
- Abate by
- Feb 8, 2013
- Penalty
- Initial $4,500 · Current $3,150 Reduced
General-duty citation text
29 CFR 1926.651(j)(2): Employees were not protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations: (a) TRENCH BETWEEN FLOW MANAGEMENT CHAMBER AND DENITRIFICATION AREA - The employer did not protect employee(s) who were installing a sixteen (16) inch sewer pipe by ensuring that the soil pile created from digging the trench was kept a minimum of two (2) feet from the edge of the trench, thereby exposing the employee(s) to cave-in hazards, on or about December 4, 2012. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $3150
- — Z (S) $4500
1926.652 A01
- Issued
- Jan 14, 2013
- Abate by
- Feb 8, 2013
- Penalty
- Initial $4,500 · Current $3,150 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(b) or (c): (a) TRENCH BETWEEN FLOW MANAGEMENT CHAMBER AND DENITRIFICATION AREA - An adequate protective system was not used when employee(s) were installing a sixteen (16) inch sewer pipe in a trench at a depth of approximately eight (8) feet, thereby exposing employees to cave-in hazards and injuries, on or about December 4, 2012. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $3150
- — Z (S) $4500
1926.651 K01
- Issued
- Jan 14, 2013
- Abate by
- Feb 8, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions: (a) TRENCH BETWEEN FLOW MANAGEMENT CHAMBER AND DENITRIFICATION AREA - The competent person did not conduct a daily inspection of the work area to detect that the spoil pile created from the soil that had been removed from the trench was placed a safe distance from the edge of the trench and that adequate protective systems were utilized to protect employee(s) performing work in the trench that was measured to be approximately eight (8) feet deep, thereby exposing employee(s) to cave-in hazards and injuries, on or about December 4, 2012. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at D.L. George & Sons Construction CO
View D.L. George & Sons Construction CO's full OSHA safety record →
More inspections in this industry (NAICS 237110)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337781215.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.