STANTON, TX —
OSHA Inspection: ENDEAVOR ENERGY RESOURCES LP
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of ENDEAVOR ENERGY RESOURCES LP in COUNTY ROAD A3900, STANTON, TX 79782 (NAICS 238210). OSHA activity number 337782023.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ENDEAVOR ENERGY RESOURCES LP
- Site address
- COUNTY ROAD A3900
- City
- STANTON
- State
- TX
- ZIP
- 79782
- Mailing
- PO BOX 60446, MIDLAND, TX 79711
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 45
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.416 A01
- Issued
- Jun 3, 2013
- Abate by
- Jun 13, 2013
- Penalty
- Initial $4,900 · Current $0 Reduced
General-duty citation text
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means: On or about December 4, 2012 employer did not ensure that electric power circuits were de-energized or grounded and did not effectively guard or insulate energized conductors, exposing an employee to electrical hazards.
Recent events (3)
- — J (S) $0
- — C (S) $4900
- — Z (S) $4900
1926.950 D01 V
- Issued
- Jun 3, 2013
- Abate by
- Jun 7, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.950(d)(1)(v): Guards or barriers shall be erected unless provision is made to insulate or isolate the workman or the energized conductor: On December 4, 2012, while stringing de-energized conductors, the employer did not guard or install a barrier on adjacent energized overhead lines, and did not insulate the workman nor insulate the energized conductor, exposing the employee to electrocution hazards.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1926.453 B02 V
- Issued
- Jun 3, 2013
- Abate by
- Jun 7, 2013
- Penalty
- Initial $3,500 · Current $0 Reduced
General-duty citation text
29 CFR 1926.453(b)(2)(v): A body belt with lanyard attached to the boom or basket was not worn by employee(s) working from an aerial lift: On December 4, 2012, a body belt or full body harness with lanyard was not worn by an employee working in the Altec aerial lift, model AM855, serial number 0706BB4108, unit number 373009, exposing the employee to fall hazards.
Recent events (3)
- — J (S) $0
- — C (S) $3500
- — Z (S) $3500
1926.950 C01
- Issued
- Jun 3, 2013
- Abate by
- Jun 7, 2013
- Penalty
- Initial $4,900 · Current $0 Reduced
General-duty citation text
29 CFR 1926.950(c)(1): Employees were permitted to approach or take a conductive object without an approved insulating handle closer to exposed energized parts than shown in Table V-1:Note: Exceptions are stated in (c)(1)(i) through (c)(1)(iii). On December 4, 2012, an employee was permitted to take grounded conductors and the Altec Model AM855 aerial lift, serial number 0706BB4108 closer than the minimum working distace of 2.0 feet from energized conductors.The employee was not wearing insulated personal protective equipment, and the energized conductors were not insulated or guarded, exposing the employee to electrocution hazards.
Recent events (3)
- — J (S) $0
- — C (S) $4900
- — Z (S) $4900
1926.952 A01
- Issued
- Jun 3, 2013
- Abate by
- Jun 13, 2013
- Penalty
- Initial $2,100 · Current $0 Reduced
General-duty citation text
29 CFR 1926.952(a)(1): Visual inspection was not made of the mechanical equipment to determine that it was in good condition each day the equipment was used: On or about December 4, 2012, employer did not ensure that the truck's overhead spot light was operative. This condition exposed employees to potential struck-by and electrical hazards.
Recent events (3)
- — J (S) $0
- — C (S) $2100
- — Z (S) $2100
1926.955 C02
- Issued
- Jun 3, 2013
- Abate by
- Jun 13, 2013
- Penalty
- Initial $4,900 · Current $0 Reduced
General-duty citation text
29 CFR 1926.955(c)(2): The employer failed to hold a job briefing prior to stringing operations that would set forth the plan of operation and specifying the type of equipment to be used, grounding devices and procedures to be followed, crossover methods to be employed, and clearance authorization: Prior to commencing stringing operations, the employer did not conduct a job briefing, did not identify the hazards of adjacent live conductors, did not specify insulating methods, crossover methods and personal protective equipment to be utilized, exposing employees to electrical hazards.
Recent events (3)
- — J (S) $0
- — C (S) $4900
- — Z (S) $4900
More inspections at Endeavor Energy Resources LP
View Endeavor Energy Resources LP's full OSHA safety record →
More inspections in this industry (NAICS 238210)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337782023.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.