Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: M M PRO SERVICES INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of M M PRO SERVICES INC. in 4025 N. CENTRAL PARK AVE., CHICAGO, IL 60618 (NAICS 238170). OSHA activity number 337926810.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch M M PRO Services INC. — free Get an email when a new federal OSHA severe-injury report for M M PRO Services INC. is published. One employer, no account, unsubscribe in one click.
Site address
4025 N. CENTRAL PARK AVE.
City
CHICAGO
State
IL
ZIP
60618
Mailing
160 W. ARLINGTON DR., ROUND LAKE, IL 60073
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
2
Ownership type
A

9 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 1 exposed
Issued
May 13, 2013
Abate by
Jun 14, 2013
Penalty
Initial $400 · Current $400
29 CFR 1903.19(c)(1):  The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:    M M Pro Services, Inc. failed to certify to OSHA within 10 calendar days after the abatement date that each of the following cited violations had been corrected:    Citation Number                     Item Number                           Abatement Date 01                                            02a                                           1/22/2013 01                                            02b                                           2/19/2013 01                                            02c                                           2/19/2013    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (O) $400

1926.100 A

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 15, 2013
Abate by
Mar 1, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.100(a):  Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns:    a)  Employees were not wearing protective helmets where there was a possible danger of head injury from falling objects.    No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.451 F03

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 15, 2013
Abate by
Mar 1, 2013
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.    a) The employer did not have a competent person inspect the pump jack scaffold and scaffold components before the work shift.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1926.454 A

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 15, 2013
Abate by
Mar 1, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.454(a):  The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards:    a)  The employer did not ensure that each employee was provided with training in the recognition and control of the hazards associated with working from scaffolding provided for employee use..    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.454 B

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 15, 2013
Abate by
Mar 1, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.454(b): The employer did not have each employee involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question.    a) The employer did not ensure each employee involved in erection of scaffolding provided for use at the site was trained in the recognition of the hazards.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 F06

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 15, 2013
Abate by
Jan 22, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6).    a) On or about December 19, 2012, the employer permitted employees to erect and use pump jack scaffolding in close proximity to insulated energized power lines having a voltage of 120/240 volts.     In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.451 G01

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 15, 2013
Abate by
Jan 22, 2013
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level.    a)  Employees were exposed to the hazard of falling while performing siding work from a pump jack scaffold elevated approximately 19 feet above the ground.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1926.405 G01 III C

Other-than-serious 1 instance 2 exposed
Issued
Jan 15, 2013
Abate by
Jan 22, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(1)(iii)(C):  Flexible cords and cables were run through doorways, windows, or similar openings.    a) An extension cord used to power tools at the site was run through a window.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.1053 B08

Other-than-serious 1 instance 1 exposed
Issued
Jan 15, 2013
Abate by
Jan 22, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(8): Ladders placed in a location where they could be displaced by workplace activities or traffic, such as in passageways, doorways, or driveways, were not secured to prevent accidental displacement, nor was a barricade used to keep the activities or traffic away from the ladder:    a) The ladder was placed on the front stairs of the building without it being secured or barricaded.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View M M PRO Services INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337926810.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.