SAINT JOSEPH, MO —
OSHA Inspection: ST. JOSEPH PLASTICS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ST. JOSEPH PLASTICS in 1102 5TH AVE, SAINT JOSEPH, MO 64505 (NAICS 423930). OSHA activity number 337949432.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ST. JOSEPH PLASTICS
- Site address
- 1102 5TH AVE
- City
- SAINT JOSEPH
- State
- MO
- ZIP
- 64505
- Mailing
- 1102 5TH AVE, SAINT JOSEPH, MO 64505
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423930
- Employees
- 58
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.178 L04 III
- Issued
- Jan 9, 2013
- Abate by
- Feb 5, 2013
- Penalty
- Initial $2,100 · Current $1,050 Reduced
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance shall be conducted at least once every three years. (a) 1102 5th Avenue Saint Joseph, MO 64505. Employees from the shipping and receiving warehouse has not beein retrained as required by the power vehicles industrial standard.
Recent events (2)
- — I (O) $1050
- — Z (S) $2100
1910.37 B01
- Issued
- Jan 9, 2013
- Abate by
- Feb 5, 2013
- Penalty
- Initial $2,100 · Current $0 Reduced
General-duty citation text
29 CFR 1910.37(b)(1): Each exit route must be adequately lighted so that an employee with normal vision can see along the exit route. (a) 1102 5th Avenue Saint Joseph, MO 64505. The emergency lights at the exit on the warehouse didn't work.
Recent events (2)
- — I (S) $0
- — Z (S) $2100
1910.305 B02 I
- Issued
- Jan 9, 2013
- Abate by
- Feb 27, 2013
- Penalty
- Initial $2,100 · Current $1,050 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear. (a) 1102 5th Avenue Saint Joseph, MO 64505. An electrical breaker panel do not have a cover at the manufacturing area.
Recent events (2)
- — I (O) $1050
- — Z (S) $2100
More inspections at ST. Joseph Plastics
View ST. Joseph Plastics's full OSHA safety record →
More inspections in this industry (NAICS 423930)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337949432.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.