Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U. S. DEPT OF NAVY

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of U. S. DEPT OF NAVY in MCHUGH BLVD., BLDG.#3 MCAS NEW RIVER, JACKSONVILLE, NC 28545 (NAICS 928110). OSHA activity number 337997225.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U. S. Dept of Navy — free Get an email when a new federal OSHA severe-injury report for U. S. Dept of Navy is published. One employer, no account, unsubscribe in one click.
Establishment
U. S. DEPT OF NAVY
Site address
MCHUGH BLVD., BLDG.#3 MCAS NEW RIVER
City
JACKSONVILLE
State
NC
ZIP
28545
Mailing
P.O. BOX 21001 MCAS NEW RIVER, JACKSONVILLE, NC 28545
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
928110
Employees
6
Ownership type
D

3 citations on file for this inspection.

1910.157 C01

Serious 1 instance 1 exposed
Issued
Jan 18, 2013
Abate by
Feb 22, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:    AS-302 PMO: Employer did not ensure portable fire extinguishers were not mounted.
Recent events (1)
  • — Z (S) $0

1910.157 E02

Serious 1 instance 1 exposed
Issued
Jan 18, 2013
Abate by
Feb 22, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:    AS-302:  Employer did not ensure Portable fire extinguishers were inspected monthly.
Recent events (1)
  • — Z (S) $0

1910.305 J02 V

Serious Gravity 1 1 instance 2 exposed
Issued
Jan 18, 2013
Abate by
Feb 22, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(j)(2)(v): A receptacle installed outdoors in a location protected from the weather or in other damp locations did not have an enclosure for the receptacle that was weatherproof.      AS-302 PMO: Employer did not use an approved weatherproof receptacle for outdoor use. Employees were exposed to shock hazards.
Recent events (1)
  • — Z (S) $0