Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: UNIQUE PLATING, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of UNIQUE PLATING, INC. in 66 MILL STREET, JOHNSTON, RI 02919 (NAICS 339913). OSHA activity number 338023013.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Unique Plating, INC. — free Get an email when a new federal OSHA severe-injury report for Unique Plating, INC. is published. One employer, no account, unsubscribe in one click.
Site address
66 MILL STREET
City
JOHNSTON
State
RI
ZIP
02919
Mailing
66 MILL STREET, JOHNSTON, RI 02919
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339913
Employees
10
Ownership type
A

11 citations on file for this inspection.

1910.36 D

Other-than-serious 1 instance 10 exposed
Issued
Feb 5, 2013
Abate by
Mar 10, 2013
Penalty
Initial $1,080 · Current $0 Reduced
29 CFR 1910.36(d): Employees were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge:    Facility, east end of the building: An exit door, labelled as a means of employee egress in the event of an emergency, could not be opened during working hours.  The door knob was locked or frozen, and the door jammed shut in a manner that prevented it from opening.
Recent events (2)
  • — I (O) $0
  • — Z (S) $1080

1910.37 A03

Other-than-serious 1 instance 10 exposed
Issued
Feb 5, 2013
Abate by
Mar 10, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(3):     Exit routes must be free and unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route:           Exit door, next to Assembly Area: Access to the exit door was blocked by storage of materials including, but not limited to, metal racks and boxes.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.134 C01

Deleted Serious Gravity 1 1 instance 2 exposed
Issued
Feb 5, 2013
Abate by
Mar 10, 2013
Penalty
Initial $1,080 · Current $0 Reduced
29 CFR 1910.134(c)(1):     In any workplace where respirators are necessary to protect the health of the employee or whenever respirators are required by the employer, the employer shall establish and implement a written respiratory protection program with worksite-specific procedures:    Facility: When the employer supplied a half-mask elastomeric respirator for use in the event of a chemical spill, he did not develop and implement a written respiratory protection program as outlined in 1910.134(c)(1)(i) through (ix).
Recent events (2)
  • — I (S) $0
  • — Z (S) $1080

1910.134 D03 II

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Feb 5, 2013
Abate by
Feb 13, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(d)(3)(ii):     The respirator selected shall be appropriate for the chemical state and physical form of the contaminant:        Facility: When selecting a respirator as protection during the clean-up of a spill of liquid acids, the employer selected a half-mask elastomeric respirator outfitted with HEPA cartridges.  These cartridges are ineffective agaist the acid gas vapors that would be generated.  The appropriate selection are those cartridges offering protection against acid gas vapors.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 E01

Deleted Serious Gravity 1 2 instances 2 exposed
Issued
Feb 5, 2013
Abate by
Mar 10, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1):     The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace:    Facility: Employees assigned to wear a half-mask eleastomeric respirator during acid spill clean-ups have not received a medical evaluation to ensure the employee's ability to use the respirator.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 F01

Deleted Serious Gravity 1 2 instances 2 exposed
Issued
Feb 5, 2013
Abate by
Mar 10, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(1):     The employer shall ensure that employees using a tight-fitting facepiece respirator pass an appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT) as stated in this paragraph:      Facility: Employees assigned to wear a tight-fitting elastomeric respirator when cleaning up acid spills had not received an appropriate qualitative or quantitative fit test.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 K01

Deleted Serious Gravity 1 1 instance 2 exposed
Issued
Feb 5, 2013
Abate by
Mar 10, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(1):     The employer shall ensure that each employee can demonstrate knowledge of at least the following respiratory requirements:      Facility: When employees were assigned to wear tight-fitting eleastomeric respirators to clean up an acid spill, the employer did not ensure the employees had received training in the respiratory requirements outlined in 29 CFR 1910.134(k)(1)(i) through (vii).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.141 A03 III

Serious Gravity 1 10 instances 10 exposed
Issued
Feb 5, 2013
Abate by
Feb 28, 2013
Penalty
Initial $1,080 · Current $1,000 Reduced
29 CFR 1910.141(a)(3)(iii):     To facilitate cleaning, every floor, working place, and passageway shall be kept free from protruding nails, splinters, loose boards, and unnecessary holes and openings.    Facility: In the Plating and Wastewater Treatment Areas the employer used wooden flooring to raise up the walking and working surfaces. This raised flooring had numerous sections of missing and broken floor boards, and open holes in the flooring.  This created slip and tripping hazards and uneven and unstable walking surfaces for employees handling hazardous chemicals, and also in the event emergency egress is required.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1080

1910.303 F02

Serious Gravity 1 3 instances 10 exposed
Issued
Feb 5, 2013
Abate by
Feb 12, 2013
Penalty
Initial $1,080 · Current $1,000 Reduced
29 CFR 1910.303(f)(2):     Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident.        Plating Area: In the electrical panel that controls the lighting and power for the plating equipment, the employer did not label or identify individual circuits.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1080

1910.303 G01 II

Serious Gravity 1 1 instance 10 exposed
Issued
Feb 5, 2013
Abate by
Feb 15, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii):     Working space required by this standard may not be used for storage:      The employer allowed storage of plating equipment and other materials within 3 feet of an electrical panel in the Plating Area.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 1 1 instance 10 exposed
Issued
Feb 5, 2013
Abate by
Feb 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii):     Unused openings in cabinets, boxes, and fittings shall be effectively closed:      The employer did not effectively close all openings inside the circuit box that energizes the lighting and plating equipmentin the Plating Area.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Unique Plating, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338023013.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.