ASHLAND, NY —
OSHA Inspection: HUBBELL, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HUBBELL, INC. in 12094 HIGHWAY 23, ASHLAND, NY 12407 (NAICS 237110). OSHA activity number 338128416.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HUBBELL, INC.
- Site address
- 12094 HIGHWAY 23
- City
- ASHLAND
- State
- NY
- ZIP
- 12407
- Mailing
- PO BOX 664, MARGARETVILLE, NY 12455
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 8
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.153 H05
- Issued
- Feb 1, 2013
- Abate by
- Feb 13, 2013
- Penalty
- Initial $1,600 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.153(h)(5): Valves on LP-Gas containers having water capacity greater than 50 pounds (nominal 20 pounds LP-Gas capacity) were not protected from damage while in use or storage: a) Jobsite, near new pump house; On or about 01/07/2013; Two LP tanks did not have protective covers on the valves while being used at the jobsite for heat.
Recent events (2)
- — I (S) $1200
- — Z (S) $1600
1926.153 H11
- Issued
- Feb 1, 2013
- Penalty
- Initial $1,360 · Current $1,020 Reduced
General-duty citation text
29 CFR 1926.153(h)(11): Containers having a water capacity greater than 2 pounds (nominal 1 pound LP-Gas capacity) connected for use did not stand on a firm and substantial surface and, when necessary, were not secured in an upright position: a) Jobsite, near new pump house; on or about 01/07/2013; a 100 gallon capacity LP tank that was fueling the propane heater was not secured in the snow.
Recent events (2)
- — I (S) $1020
- — Z (S) $1360
1926.153 H13
- Issued
- Feb 1, 2013
- Penalty
- Initial $1,600 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.153(h)(13): For temporary heating, heaters (other than integral heater-container units) were not located at least 6 feet from any LP-Gas container: a) a) Jobsite, near new pump house; on or about 01/07/2013; The "Mr. Heater Contractor Series" heater 75,000 - 125,000 BTU per hour was operating next to the tank exposing employees to explosion and burn hazards.
Recent events (2)
- — I (S) $1200
- — Z (S) $1600
1926.153 O
- Issued
- Feb 1, 2013
- Abate by
- Feb 11, 2013
- Penalty
- Initial $1,360 · Current $1,020 Reduced
General-duty citation text
29 CFR 1926.153(o): When damage to LP-Gas systems from vehicular traffic was a possibility, precautions against such damage were not taken: a) Jobsite, near new pump house; on or about 01/07/2013; Two 100 Gallon capacity LP tanks were stored underneath the all-terrain fork truck exposing employees to explosion and burn hazards.
Recent events (2)
- — I (S) $1020
- — Z (S) $1360
More inspections at Hubbell, INC.
View Hubbell, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 237110)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338128416.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.