Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ADVANCED MANUFACTURING & POWER SYSTEMS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ADVANCED MANUFACTURING & POWER SYSTEMS, INC. in 1965 BENNETT DRIVE, DELAND, FL 32724 (NAICS 332420). OSHA activity number 338137243.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Advanced Manufacturing & Power Systems, INC. — free Get an email when a new federal OSHA severe-injury report for Advanced Manufacturing & Power Systems, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1965 BENNETT DRIVE
City
DELAND
State
FL
ZIP
32724
Mailing
1965 BENNETT DRIVE, DELAND, FL 32724
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332420
Employees
16
Ownership type
A

7 citations on file for this inspection.

1910.179 J01 II B

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 22, 2013
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.179(j)(1)(ii)(b): Periodic inspection were not conducted:    a. On or about January 7, 2013, the 10-ton overhead crane had not been inspected since 2008.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.179 L03 III D

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 22, 2013
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.179(l)(3)(iii)(d): Pendant control stations were not kept clean, and/or their function labels were not kept legible:    a. On or about January 7, 2013, the east/west travel function keys on the pennant unit for the Detroit 10-ton overhead crane were not legible.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.180 D01

Serious Gravity 5 1 instance 4 exposed
Issued
Feb 22, 2013
Abate by
Apr 10, 2013
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.180(d)(1): Prior to initial use all new and altered cranes were not inspected to insure compliance with provisions of this section:    a. On or about January 7, 2013, the Bantam wheel mounted crane's load block was altered, the crane was not inspected after the alteration.    Or in the alternative:    OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to being struck by suspended loads:    a. On or about January 7, 2013, the Bantam wheel mounted crane's load block was altered, the crane was not inspected after the alteration.    Among other methods, one feasible and acceptable abatement methods to correct this hazard is to have the crane tested in accordance  ANSI B30.5-2011 Section 5-2.1: Inspection, 5-2.1.1 (a) Initial inspection
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.107 B05 I

Other-than-serious 1 instance 1 exposed
Issued
Feb 22, 2013
Abate by
Apr 10, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.107(b)(5)(i): The employer did not have visible gauges, audible alarms, or pressure activated devices installed to indicate or ensure that he required air velocity was maintained on a spray booth:    a. On or about January 7, 2012, the spray booth did not have visible gauges, audible alarms, or pressure activated devices installed to indicate or ensure that the required air velocity was maintained, exposing employees to the potential of exposure hazardous products such as but not limited to; DTM Polyurethane, EPX 900, EPX 901, parachloribenzotriflou, and acetyl acetone.
Recent events (1)
  • — Z (O) $0

1910.107 C02

Other-than-serious 1 instance 1 exposed
Issued
Feb 22, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.107(c) (2): Open flame or spark producing equipment was not kept from a spraying area or within 20 feet, unless separated from by a partition:    a. On or about January 7, 2013, in the spray booth, there was an electrically operated air compressor 9-foot from the spray booth.
Recent events (1)
  • — Z (O) $0

1910.107 E02

Other-than-serious 1 instance 1 exposed
Issued
Feb 22, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.107(e)(2): The quantity of flammable or combustible liquids kept in the vicinity of spraying operations were not at a minimum required for operations or they exceeded a supply for one day or one shift.     a. On or about January 7, 2013, the amount of flammable or combustable liquids kept in the vicinity of the spray operations exceeded the supply needed for one day.
Recent events (1)
  • — Z (O) $0

1910.107 G07

Other-than-serious 1 instance 1 exposed
Issued
Feb 22, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.107(g)(7): "No smoking" signs in large letters on contrasting color backgrounds were not conspicuously posted at all spraying areas and the paint storage rooms:     a. On or about January 7, 2013, in the spray booth area, "No smoking" signs were not posted.
Recent events (1)
  • — Z (O) $0

View Advanced Manufacturing & Power Systems, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338137243.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.