Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ADVANCED MANUFACTURING & POWER SYSTEMS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ADVANCED MANUFACTURING & POWER SYSTEMS, INC. in 1965 BENNETT DRIVE, DELAND, FL 32724 (NAICS 332420). OSHA activity number 343927463.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Advanced Manufacturing & Power Systems, INC. — free Get an email when a new federal OSHA severe-injury report for Advanced Manufacturing & Power Systems, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1965 BENNETT DRIVE
City
DELAND
State
FL
ZIP
32724
Mailing
1965 BENNETT DRIVE, DELAND, FL 32724
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332420
Employees
60
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 2 exposed
Issued
Jun 10, 2019
Penalty
Initial $9,282 · Current $5,569 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, exposing them to crushing hazards.  a. On or about April 12, 2019 an employee was operating a forklift that did not have a seat belt installed, exposing employees to crushing hazards.
Recent events (2)
  • — I (S) $5569.2
  • — Z (S) $9282

1910.22 D01

Other-than-serious 1 instance 5 exposed
Issued
Jun 10, 2019
Penalty
Initial $744 · Current $446 Reduced
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate.  A). On or about April 12, 2019, office space ceiling area was used for storage for the fabrication shop and was not labeled with approved loads, exposing employees to a structural collapse.