Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NORFOLK SOUTHERN RAILWAY COMPANY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of NORFOLK SOUTHERN RAILWAY COMPANY in 200 NORTH 4TH AVENUE, ALTOONA, PA 16601 (NAICS 482111). OSHA activity number 338138829.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Norfolk Southern Railway Company — free Get an email when a new federal OSHA severe-injury report for Norfolk Southern Railway Company is published. One employer, no account, unsubscribe in one click.
Site address
200 NORTH 4TH AVENUE
City
ALTOONA
State
PA
ZIP
16601
Mailing
200 NORTH 4TH AVENUE, ALTOONA, PA 16601
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
482111
Employees
200
Ownership type
A

5 citations on file for this inspection.

1910.147 C04 I

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Jun 11, 2013
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:   (a) Facility, Boiler Number One: On or before January 3, 2013, employees were working unprotected and exposed to steam and or hot water while performing work on a steam header valve and during the cleanup activities post incident. The employer did not develop an energy control procedure for the work being performed on or near the steam header valve.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7000

1910.147 D04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 11, 2013
Penalty
Initial $0 · Current $5,250
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:     (a) Facility, Steam Header Valve on Boiler Number One: On or about before January 3, 2013, no lock or tag was affixed to an energy isolating device on the steam field valve while employees were working on the steam header valve.
Recent events (2)
  • — I (S) $5250
  • — Z (S) $0

1910.147 C06 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 11, 2013
Abate by
Aug 30, 2013
Penalty
Initial $5,000 · Current $3,750 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed:     (a) Facility: On or before January 3, 2013, the employer did not document annual or a more frequent inspection of authorized employees isolating hazardous energy sources.
Recent events (2)
  • — I (S) $3750
  • — Z (S) $5000

1910.147 C07 III A

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 11, 2013
Abate by
Aug 30, 2013
Penalty
Initial $5,000 · Current $3,750 Reduced
29 CFR 1910.147(c)(7)(iii)(A): Retraining was not provided for authorized and affected employees when there was a change in their job assignments, a change in machines, equipment or processes that presented a new hazard, or when there was a change in the energy control procedures:     (a) Facility, Boiler Number One: On or before January 3, 2013, the employer did not provide retraining for employees to locate isolation procedures, use verification techniques, and/or how to effectively bleed off stored energy for the boiler system.
Recent events (2)
  • — I (S) $3750
  • — Z (S) $5000

1910.147 C05 II D

Other-than-serious 2 instances 1 exposed
Issued
Jun 11, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(5)(ii)(D): Lockout devices and tagout devices did not indicate the identity of the employee applying the device(s):   (a) Facility, Boiler Number One: On or before January 3, 2013, employees did not identify who installed a chain and lock used to isolate the Non-Return valve.     (b) Facility, Boiler Number One: On or before January 3, 2013, employees did not identify who installed a chain and lock used to isolate the Steam Header valve.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Norfolk Southern Railway Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338138829.