Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DIAMOND, INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of DIAMOND, INC. in 42 CENTURY DRIVE, BRISTOL, CT 06010 (NAICS 238160). OSHA activity number 338154628.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Diamond, INC. — free Get an email when a new federal OSHA severe-injury report for Diamond, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
DIAMOND, INC.
Site address
42 CENTURY DRIVE
City
BRISTOL
State
CT
ZIP
06010
Mailing
99 BROOKSIDE ROAD, WATERBURY, CT 06708
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
10
Ownership type
A

5 citations on file for this inspection.

1926.150 C01 VI

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 4, 2013
Abate by
Mar 8, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.150(c)(1)(vi): A fire extinguisher, rated not less than 10B, was not provided within 50 feet of wherever more than 5 gallons of flammable or combustible liquids or 5 pounds of flammable gas are being used on the jobsite. This requirement does not apply to the integral fuel tanks of motor vehicles.    On or about 01/09/2013 at the Doubletree Hotel renovation project, employees were using a 20 pound rated propane tank and 3 gallons of flammable QuickPrime Plus adhesive on a roof with no fire extinguisher within 50 feet.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.503 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 28, 2013
Abate by
Feb 28, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(1):  The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:    On or about 01/09/2013 at the Doubletree Hotel renovation project, the employees were not trained on fall protection requirements and usage of fall protection while working on an ice covered roof.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.150 C01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 28, 2013
Abate by
Mar 6, 2013
Penalty
Initial $2,200 · Current $1,320 Reduced
29 CFR 1926.150(c)(1)(i):  Travel distance from any point of the protected area to the nearest fire extinguisher exceeded 100 feet:    On or about 01/09/2013 at the Doubletree Hotel renovation project, employees were working on a roof using a torch, propane, and flammable roof adhesive and the nearest fire extinguisher was located on the ground in the company truck located approximately 250 feet travel distance, to and from.
Recent events (3)
  • — F (S) $1320
  • — C (S) $2200
  • — Z (S) $2200

1926.21 B05

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 28, 2013
Abate by
Apr 16, 2013
Penalty
Initial $2,200 · Current $2,200
29 CFR 1926.21(b)(5):   Employee(s) required to handle or use flammable liquids, gases, or toxic materials were not instructed in the safe handling and use of these materials and made aware of the specific requirements contained in 29 CFR 1926, subparts D, F, and other applicable subparts of this part.    On or about 01/09/2013 at the Doubletree Hotel renovation project, employees were exposed to fire hazards while working with flammable liquids/gas such as QuickPrime Plus adhesives and propane.  The employees did not know the fire extinguisher requirements or of not working within 50 feet of flammables while using a torch.
Recent events (3)
  • — F (S) $2200
  • — C (S) $2200
  • — Z (S) $2200

1926.502 H01

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 28, 2013
Abate by
Feb 28, 2013
Penalty
Initial $2,200 · Current $0 Reduced
29 CFR 1926.502(h)(1):  The employer did not did not designate a competent person to monitor the safety of other employees and/or did not ensure that the safety monitor complied with the requirements listed in (h)(1)(i) through (h)(1)(v) of this section:    On or about 01/09/2013 at the Doubletree Hotel renovation project, employees were exposed to 12 foot fall hazard while working from an ice covered roof with the safety monitor system in use and the employees did not know the safety monitor duties or responsibilities.
Recent events (3)