EIELSON AFB, AK —
OSHA Inspection: AIR NATIONAL GUARD
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AIR NATIONAL GUARD in AIRCRAFT MAINTENANCE BLDG 01168, EIELSON AFB, AK 99702 (NAICS 928110). OSHA activity number 338239817.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AIR NATIONAL GUARD
- Site address
- AIRCRAFT MAINTENANCE BLDG 01168
- City
- EIELSON AFB
- State
- AK
- ZIP
- 99702
- Mailing
- 2680 FLIGHTLINE AVE STE 117, EIELSON AFB, AK 99702
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 928110
- Employees
- 112
- Ownership type
- D
Citations
5 citations on file for this inspection.
1910.212 A01
- Issued
- Jan 29, 2013
- Abate by
- Mar 13, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Metal Technology Shop: On or about 8 January 2013 and times prior thereto, the Standard-Modern Lathe, Model 19/36x54 (Machine 3) did not have a chuck guard installed. This condition exposed employees to a caught in and/or struck by hazard.
Recent events (1)
- — Z (S) $0
1910.253 B02 II
- Issued
- Jan 29, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders was not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons. Metal technology Shop: On or about 8 January 2013 and times prior thereto, a 33 gallon propane tank was located in the back portion of the shop not secured. This condition exposed employees to a struck by hazard.
Recent events (1)
- — Z (S) $0
1910.303 F02
- Issued
- Jan 29, 2013
- Abate by
- Feb 27, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident. Metal Technology Shop: On or about 8 January 2013 and times prior thereto, the 120 volt, Circuit Breaker panel (PNL-LB)not fully labeled with all circuits installed. This exposed employees to an electrical shock hazard.
Recent events (1)
- — Z (S) $0
1910.303 G01 I B
- Issued
- Jan 29, 2013
- Abate by
- Feb 27, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(i)(B): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the width of the working space in front of electrical equipment was less than the width of the equipment or 762 mm (30 inches), whichever was greater. Electrical-Environmental Shop: On or about 8 January 2013 and times prior thereto, the electrical panel in the testing room was blocked. This condition exposed employees to smoke inhalation hazards in delays in isolating the system.
Recent events (1)
- — Z (S) $0
1910.305 G02 III
- Issued
- Jan 29, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws. Avionics Shop: On or about 8 January 2013 and times prior thereto, the 25 foot blue extension cord (shop # A9MVEXTNA) exhibited strain relief on the electrical plug exposing wires. This condition exposed employees to a 120 volt electrical shock hazard.
Recent events (1)
- — Z (S) $0
More inspections at AIR National Guard
View AIR National Guard's full OSHA safety record →
More inspections in this industry (NAICS 928110)
More inspections in AK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338239817.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.