On , OSHA opened a complaint health inspection of MINCEY MARBLE MFG, INC. in 3942 HIDDEN HILLS DRIVE, GAINESVILLE, GA 30503 (NAICS 325211). OSHA activity number 338247216.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mincey Marble MFG, INC. — free Get an email when a new federal OSHA severe-injury report for Mincey Marble MFG, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3942 HIDDEN HILLS DRIVE
City
GAINESVILLE
State
GA
ZIP
30503
Mailing
4321 BROWNS BRIDGE ROAD, GAINESVILLE, GA 30503
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325211
Employees
130
Ownership type
A

8 citations on file for this inspection.

1910.37 B02

Serious Gravity 1 1 instance 48 exposed
Issued
Jul 3, 2013
Penalty
Initial $2,700 · Current $1,620 Reduced
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":   On or about January 14, 2013:   Employees working in the Panel Plant production areas were exposed to burns and smoke inhalation hazards where exit doors were not marked with an "EXIT" sign.  Flammable liquids are sprayed and used in the facility daily.  The employer had not marked the designated exit doors.
Recent events (2)
  • — I (S) $1620
  • — Z (S) $2700

1910.107 C06

Serious Gravity 5 2 instances 4 exposed
Issued
Jul 3, 2013
Abate by
Aug 23, 2013
Penalty
Initial $4,500 · Current $2,700 Reduced
29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations:    On or about January 14, 2013:    Employees working in the spray area are exposed to explosion and fire hazards where flammable chemicals such as, but not limited Gel-Coat and Norox MEKP-900 are sprayed daily.  The employer did not ensure that lights and other electrical items within the flammable spray area were explosion proof.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $4500

1910.107 E02

Deleted Serious Gravity 10 1 instance 48 exposed
Issued
Jul 3, 2013
Abate by
Jul 23, 2013
Penalty
Initial $6,300 · Current $0 Reduced
29 CFR 1910.107(e)(2): Quantity.  Bulk storage of portable containers of flammable liquids or liquids with a flashpoint greater than 199.4 °F (93 °C) shall be in a separate, constructed building detached from other important buildings or cut off in a standard manner.   On or about January 14, 2013:   Employees working in the Panel Plant production area are exposed to fire and smoke hazards due to flammable chemicals such as, but not limited to Gel-Coat being improperly stored in the production area.  There were more than 800 gallons of flammable liquid in the area.  The employer did not ensure that flammable liquids were stored in a flammable storage room or building.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6300

1910.107 M01

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 3, 2013
Abate by
Aug 23, 2013
Penalty
Initial $4,500 · Current $2,700 Reduced
29 CFR 1910.107(m)(1): Spraying operations involving the use of organic peroxides and other dual component coatings were not conducted in approved sprinklered spray booths meeting the requirements of this section:    On or about January 14, 2013:   Employees working in the spray areas are exposed to fire hazards due to the use of MEKP-900, an organic peroxide catalyst with the flammable liquid gel-coat.  The employer did not ensure that the operations was conducted in a spray booth meeting the requirements of this standard.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $4500

1910.141 A03 I

Serious Gravity 1 1 instance 48 exposed
Issued
Jul 3, 2013
Abate by
Jul 23, 2013
Penalty
Initial $2,700 · Current $1,620 Reduced
29 CFR 1910.141(a)(3)(i): Sanitation - Places of employment were not kept clean to the extent that the nature of the work allowed.   On or about January 14, 2013:    Employees working in the Panel Plant production area were exposed to unsanitary conditions due to the overflow of trash in the employee restroom stalls and the lack of seats on the toilets.  The employer did not maintain the restroom in a sanitary condition.
Recent events (2)
  • — I (S) $1620
  • — Z (S) $2700

1910.107 G07

Other-than-serious 1 instance 8 exposed
Issued
Jul 3, 2013
Abate by
Jul 23, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.107(g)(7): NO SMOKING signs in large letters on contrasting color background were not conspicuously posted at all spraying areas and paint storage rooms:   On or about January 14, 2013:   Employees working in or near the spraying areas were exposed to fire and smoke hazards from the spraying of flammable liquids.  The employer did not ensure that "no smoking" signs were placed in the area.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.107 M02

Other-than-serious 1 instance 48 exposed
Issued
Jul 3, 2013
Abate by
Jul 23, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.107(m)(2): No Smoking signs were not prominently displayed in any area where organic peroxides were stored, mixed or applied:   On or about January 14, 2013:   Employees were exposed to fire and smoke hazards while working in or near the areas where organic peroxides such as, but not limited to Norox MEKP-900 were stored, mixed and applied.  The employer did not ensure that no smoking signs were placed in these areas.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.138 A

Other-than-serious 1 instance 5 exposed
Issued
Jul 3, 2013
Abate by
Jul 23, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion; punctures; chemical burns; thermal burns; and harmful temperature extremes.  On or about January 14, 2013:   Employees working in the set-up area were exposed to skin hazards from utilizing chemicals such as, but not limited to Chemlease PMR and Chemlease Mold Cleaner without the use of gloves.  The employer did not ensure that employees wiping down the cast tile molds were using gloves.