EIELSON AFB, AK —
OSHA Inspection: ARMY AND AIR FORCE EXCHANGE SERVICE
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ARMY AND AIR FORCE EXCHANGE SERVICE in 451 BROADWAY AVE, EIELSON AFB, AK 99702 (NAICS 493110). OSHA activity number 338264419.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARMY AND AIR FORCE EXCHANGE SERVICE
- Site address
- 451 BROADWAY AVE
- City
- EIELSON AFB
- State
- AK
- ZIP
- 99702
- Mailing
- 451 BROADWAY AVE, EIELSON AFB, AK 99702
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493110
- Employees
- 59
- Ownership type
- D
Citations
5 citations on file for this inspection.
1910.29 F01
- Issued
- Jan 29, 2013
- Abate by
- Feb 27, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.29(f)(1): "Design." Units shall comply with applicable requirements of paragraph (a) of this section. Warehouse Area: On or about 9 January 2013 and times prior thereto, the Yellow 5-step portable ladder stand was missing the rubber floor cushions. This condition exposed employees to a fall hazard.
Recent events (1)
- — Z (S) $0
1910.101 B
- Issued
- Jan 29, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6: Warehouse area: On or about 9 January 2013 and times prior thereto, a gaseous Helium cylinder was not secured. This condition exposed employees to a struck by hazard.
Recent events (1)
- — Z (S) $0
1910.303 F02
- Issued
- Jan 29, 2013
- Abate by
- Feb 27, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident. Labeling Room, Warehouse area: On or about 9 January 2013 and times prior thereto, the electrical panel was not labeled identifying the circuits and what they controlled. This exposed employees to an electrical shock hazard.
Recent events (1)
- — Z (S) $0
1910.303 G02 I
- Issued
- Jan 29, 2013
- Abate by
- Feb 27, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i). a) Warehouse area: On or about 9 January 2013 and times prior thereto, the electrical lighting above the empty box storage area and exposed wires. This condition exposed employees to 120 volt electrical shock and burn hazards. b) Warehouse area. Center wall area: On or about 9 January 2013 and times prior thereto, an electrical outlet and junction box had exposed wires. This condition exposed employees to 120 volt electrical shock and burn hazards.
Recent events (1)
- — Z (S) $0
1910.305 G02 III
- Issued
- Jan 29, 2013
- Abate by
- Feb 27, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws Warehouse area: On or about 9 January 2013 and times prior thereto, an orange extension cord exhibited damaged strain relief on the electrical plug, exposing wires. This condition exposed employees to a 120 volt electrical shock hazard.
Recent events (1)
- — Z (S) $0
More inspections at Army and AIR Force Exchange Service
View Army and AIR Force Exchange Service's full OSHA safety record →
More inspections in this industry (NAICS 493110)
More inspections in AK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338264419.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.