Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ARMY AND AIR FORCE EXCHANGE SERVICE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ARMY AND AIR FORCE EXCHANGE SERVICE in 451 BROADWAY AVE, EIELSON AFB, AK 99702 (NAICS 493110). OSHA activity number 338264419.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Army and AIR Force Exchange Service — free Get an email when a new federal OSHA severe-injury report for Army and AIR Force Exchange Service is published. One employer, no account, unsubscribe in one click.
Site address
451 BROADWAY AVE
City
EIELSON AFB
State
AK
ZIP
99702
Mailing
451 BROADWAY AVE, EIELSON AFB, AK 99702
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493110
Employees
59
Ownership type
D

5 citations on file for this inspection.

1910.29 F01

Serious Gravity 1 1 instance 5 exposed
Issued
Jan 29, 2013
Abate by
Feb 27, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.29(f)(1):     "Design." Units shall comply with applicable requirements of paragraph (a) of this section.      Warehouse Area:  On or about 9 January 2013 and times prior thereto, the Yellow 5-step portable ladder stand was missing the rubber floor cushions.  This condition exposed employees to a fall hazard.
Recent events (1)
  • — Z (S) $0

1910.101 B

Serious Gravity 1 1 instance 6 exposed
Issued
Jan 29, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.101(b):     The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:    Warehouse area:  On or about 9 January 2013 and times prior thereto, a gaseous Helium cylinder was not secured.  This condition exposed employees to a struck by hazard.
Recent events (1)
  • — Z (S) $0

1910.303 F02

Serious Gravity 1 1 instance 6 exposed
Issued
Jan 29, 2013
Abate by
Feb 27, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(f)(2):     Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident.    Labeling Room, Warehouse area:  On or about 9 January 2013 and times prior thereto, the electrical panel was not labeled identifying the circuits and what they controlled.  This exposed employees to an electrical shock hazard.
Recent events (1)
  • — Z (S) $0

1910.303 G02 I

Serious Gravity 1 3 instances 6 exposed
Issued
Jan 29, 2013
Abate by
Feb 27, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(2)(i):     Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i).    a) Warehouse area:  On or about 9 January 2013 and times prior thereto, the electrical lighting above the empty box storage area and exposed wires.  This condition exposed employees to 120 volt electrical shock and burn hazards.    b) Warehouse area. Center wall area:  On or about 9 January 2013 and times prior thereto, an electrical outlet and junction box had exposed wires.  This condition exposed employees to 120 volt electrical shock and burn hazards.
Recent events (1)
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 1 1 instance 5 exposed
Issued
Jan 29, 2013
Abate by
Feb 27, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii):     Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws      Warehouse area:  On or about 9 January 2013 and times prior thereto, an orange extension cord exhibited damaged strain relief on the electrical plug, exposing wires.  This condition exposed employees to a 120 volt electrical shock hazard.
Recent events (1)
  • — Z (S) $0

View Army and AIR Force Exchange Service's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338264419.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.