Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PIONEER MATERIALS WEST, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PIONEER MATERIALS WEST, INC. in 7271 S. EAGLE STREET, CENTENNIAL, CO 80112 (NAICS 423320). OSHA activity number 338267826.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pioneer Materials West, INC. — free Get an email when a new federal OSHA severe-injury report for Pioneer Materials West, INC. is published. One employer, no account, unsubscribe in one click.
Site address
7271 S. EAGLE STREET
City
CENTENNIAL
State
CO
ZIP
80112
Mailing
7271 S. EAGLE STREET, CENTENNIAL, CO 80112
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423320
Employees
31
Ownership type
A

11 citations on file for this inspection.

1910.22 D01

Other-than-serious 3 instances 27 exposed
Issued
Feb 4, 2013
Penalty
Initial $1,366 · Current $1,000 Reduced
29 CFR 1910.22(d)(1):  On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed to the building:      a)  On or about January 15, 2013, and at times prior, employees were exposed to struck-by or crushed-by hazards while they worked below materials that were stored on the ceiling of the main office/breakroom area and several other storage rooms.  The employer had not posted the load rating for the roof/ceiling structure.
Recent events (2)
  • — I (O) $1000
  • — Z (S) $1366

1910.36 D01

Other-than-serious 1 instance 27 exposed
Issued
Feb 4, 2013
Penalty
Initial $1,366 · Current $1,366
29 CFR 1910.36(d)(1): Employees were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge:     a)  On or about January 15, 2013, employees were exposed to fire hazards because a door marked as a fire exit in the accoustical warehouse was damaged and could not be opened.
Recent events (2)
  • — I (O) $1366
  • — Z (S) $1366

1910.37 B02

Other-than-serious 1 instance 27 exposed
Issued
Feb 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(2):  Each exit was not clearly visible and marked by a sign reading exit:      a)  On or about January 15, 2013, and at times prior, exit signs were not provided on a designated exit in the main warehouse (by the office)  in order to inform employees and assist them in evacuating the building in the event of a fire or other emergency.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.37 B06

Other-than-serious 1 instance 27 exposed
Issued
Feb 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(6):  Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source:      a)  On or about January 15, 2013, and at times prior, the exit sign in the back of the accoustical warehouse was not illuminated by a reliable light source.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.151 C

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Feb 4, 2013
Penalty
Initial $1,366 · Current $0 Reduced
29 CFR 1910.151(c):  Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:    a)  On or about January 15, 2013, and at times prior, employees were exposed to eye injuries while they used corrosive vehicle washing chemicals such as Dirt Blaster Truck Wash  and Red Thunder in a power washer without access to a suitable eyewash facility in the immediate area.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1366

1910.305 B02 I

Other-than-serious 1 instance 27 exposed
Issued
Feb 4, 2013
Penalty
Initial $2,276 · Current $2,276
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings were not provided with covers identified for the purpose. In completed installations, each outlet box did not have a cover, faceplate, or fixture canopy:    a)  On or about January 15, 2013, and at times prior, employees were exposed to electrical shock while they worked around a junction box next to a back door of the main warehouse/office building which did not have an adequately installed cover.
Recent events (2)
  • — I (O) $2276
  • — Z (S) $2276

1910.334 A02 I

Other-than-serious 2 instances 27 exposed
Issued
Feb 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):    a)  On or about January 15, 2013, and at times prior, employees were exposed to electrical shock and fire hazards while they used two portable saws (miter and chop saw) with power cords that had damaged insulation.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.305 G01 IV

Deleted Serious Gravity 5 2 instances 27 exposed
Issued
Feb 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv):  Flexibles cords and cables were used for purposes prohibited by subparagraphs (a) through (e) of this paragraph:     a)  On or about January 15, 2013, and at times prior, employees were exposed to electrical shock and fire hazards because flexible cords and power strips were attached to building surfaces in the maintenance garage.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.334 A03 I

Other-than-serious 1 instance 27 exposed
Issued
Feb 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(3)(i):  A flexible cord used with grounding-type equipment did not contain an electric grounding conductor:    a)  On or about January 15, 2013, and at times prior, employees were exposed to electrical shock and fire hazard while they used two portable saws (miter and chop saw) that were missing grounding pins.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.1200 G08

Other-than-serious 1 instance 27 exposed
Issued
Feb 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required material safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work shift to employees when they were in their work area(s):    a)  On or about January 15, 2013, and at times prior, employees working with a variety of hazardous chemicals did not have access to information pertaining to the hazards of those chemicals because the employer did not maintain material safety data sheets for all of the chemicals used in the workplace.  In particular, the employer did not have an MSDS for the corrosive Red Thunder used to wash vehicles.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1904.32 A01

Other-than-serious 2 instances 31 exposed
Issued
Feb 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1904.32(a)(1): The employer did not review the OSHA 300 Log to verify that the entries are complete and accurate, and correct any deficiencies identified:    a) The employer did not ensure that a company officer reviewed the OSHA 300 Log for 2010 and signed the 300A annual summary form certifying that entries were complete and accurate.  One injury on the log was reported as an "other recordable" case but showed 26 days of job transfer or restriction.    b)  The employer did not ensure that a company officer reviewed the OSHA 300 Log for 2010 and signed the 300A annual summary form certifying that entries were complete and accurate.  The 300A summary form reported that employees had worked 129,684 total hours during the year when the actual hours worked was 60,448.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Pioneer Materials West, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338267826.