Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ABC POLYMER INDUSTRIES, LLC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of ABC POLYMER INDUSTRIES, LLC in 545 ELM STREET, HELENA, AL 35080 (NAICS 326199). OSHA activity number 338298813.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ABC Polymer Industries, LLC — free Get an email when a new federal OSHA severe-injury report for ABC Polymer Industries, LLC is published. One employer, no account, unsubscribe in one click.
Site address
545 ELM STREET
City
HELENA
State
AL
ZIP
35080
Mailing
545 ELM STREET, HELENA, AL 35080
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
45
Ownership type
A

8 citations on file for this inspection.

1910.178 P01

Serious Gravity 10 1 instance 3 exposed
Issued
Feb 12, 2013
Abate by
Feb 25, 2013
Penalty
Initial $4,900 · Current $2,940 Reduced
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition(s):      (a) On or about January 14, 2013 - Extrusion Area, a Toyota forklift was not removed from service when defect(s) were found such as oil leaks, an inoperable back-up alarm, and the parking brake not working properly.
Recent events (2)
  • — I (S) $2940
  • — Z (S) $4900

1910.95 G05 I

Serious Gravity 5 4 instances 8 exposed
Issued
Feb 11, 2013
Abate by
Mar 16, 2013
Penalty
Initial $2,380 · Current $1,428 Reduced

Hazardous substances 81108111

29 CFR 1910.95(g)(5)(i): The employer did not establish, within 6 months of an employee's first exposure at or above the action level, a valid baseline audiogram against which subsequent audiograms can be compared:    (a) On or about January 14, 2013 - Extrusion Line Operator 2, an employee was exposed to continuous noise levels at 87% of the allowable 8-hour time-weighted average level (85 dBA). The equivalent dBA of the employee is approximately 89 dBA. The sampling was performed for 476 minutes during one shift on January 23, 2013. Zero exposure was assumed for the unsampled time period of 4 minutes.    (b) On or about January 14, 2013 - Extrusion Line Operator 1, an employee was exposed to continuous noise levels at 191% of the allowable 8-hour time-weighted average level (85 dBA). The equivalent dBA of the employee is approximately 94 dBA. The sampling was performed for 480 minutes during one shift on January 23, 2013.     (c) On or about January 14, 2013 - Extrusion Line Operator 3, an employee was exposed to continuous noise levels at 93% of the allowable 8-hour time-weighted average level (85 dBA). The equivalent dBA of the employee is approximately 89.4 dBA. The sampling was performed for 475 minutes during one shift on January 23, 2013. Zero exposure was assumed for the unsampled time period of 5 minutes.     (d) On or about January 14, 2013 - Floater, an employee was exposed to continuous noise levels at 105% of the allowable 8-hour time-weighted average level (85 dBA). The equivalent dBA of the employee is approximately 90.3 dBA. The sampling was performed for 466 minutes during one shift on January 23, 2013. Zero exposure was assumed for the unsampled time period of 14 minutes.
Recent events (2)
  • — I (S) $1428
  • — Z (S) $2380

1910.132 A

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 11, 2013
Abate by
Feb 22, 2013
Penalty
Initial $2,380 · Current $1,428 Reduced
29 CFR 1910.132(a): Protective equipment was not provided, used, and maintained in a sanitary and reliable condition when necessary whenever hazards capable of causing injury and impairment were encountered:      (a) On or about January 14, 2013 - Water Treatment Area, face and hand protection were not provided to employees exposed to chemical hazards from corrosive material such as, but not limited to, Solen 1260.
Recent events (2)
  • — I (S) $1428
  • — Z (S) $2380

1910.132 D01

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 11, 2013
Abate by
Feb 22, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards were present, or were likely to be present, which necessitated the use of personal protective equipment:      (a) On or about January 14, 2013 - Water Treatment Area, the task of adding chemicals to the water treatment tank was not assessed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B02

Serious Gravity 1 1 instance 2 exposed
Issued
Feb 11, 2013
Abate by
Feb 22, 2013
Penalty
Initial $1,785 · Current $1,071 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:      (a) On or about January 14, 2013 - Shipping Area, two (2) extension cords were series connected to a surge protector (RPT).
Recent events (2)
  • — I (S) $1071
  • — Z (S) $1785

1910.304 G05

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 11, 2013
Abate by
Feb 22, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:      (a) On or about January 14, 2013 - Shipping Area, an extension cord was missing the grounding prong.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B02 I

Serious Gravity 1 1 instance 2 exposed
Issued
Feb 11, 2013
Abate by
Feb 22, 2013
Penalty
Initial $1,785 · Current $1,071 Reduced
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:      (a) On or about January 14, 2013 - Supervisor's Office, electrical receptacles were not covered.
Recent events (2)
  • — I (S) $1071
  • — Z (S) $1785

1910.178 L04 III

Other-than-serious 1 instance 1 exposed
Issued
Feb 11, 2013
Abate by
Feb 24, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years:      (a) On or about January 14, 2013 - Facility, refresher training was not provided every three years to forklift operators.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View ABC Polymer Industries, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338298813.