OSHA Inspection: JOHNSTOWN WIRE TECHNOLOGIES, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of JOHNSTOWN WIRE TECHNOLOGIES, INC. in 124 LAUREL AVENUE, JOHNSTOWN, PA 15906 (NAICS 331222). OSHA activity number 338371248.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Johnstown Wire Technologies, INC. — free Get an email when a new federal OSHA severe-injury report for Johnstown Wire Technologies, INC. is published. One employer, no account, unsubscribe in one click.
Site address
124 LAUREL AVENUE
City
JOHNSTOWN
State
PA
ZIP
15906
Mailing
124 LAUREL AVENUE, JOHNSTOWN, PA 15906
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331222
Employees
262
Ownership type
A

6 citations on file for this inspection.

1910.95 G06

Serious Gravity 1 2 instances 2 exposed
Issued
May 3, 2013
Abate by
May 3, 2013
Penalty
Initial $3,000 · Current $2,040 Reduced

Hazardous substances 8111

29 CFR 1910.95(g)(6): The employer did not obtain a new audiogram annually for each employee exposed to noise at or above an 8 hour time weighted average exposure of 85 decibels:     a)  At the facility, on or about March 6, 2013 - Audiograms were not conducted annually for wire drawers.  A Set 36 Wire Drawer was exposed to a dose of 90.77 %.  90.77 % is equivalent to 89.2 dBA (8-hour time weighted average).  This noise survey was conducted on March 6, 2013 for a period of 450 minutes.  Zero exposure was assumed for the unsampled time period of 30 minutes.    b)  At the facility, on or about March 6, 2013 - Audiograms were not conducted annually for wire drawers.  A Set 4 Wire Drawer was exposed to a dose of 68.65 %.  68.65 % is equivalent to 87.2 dBA (8-hour time weighted average).  This noise survey was conducted on March 6, 2013 for a period of 361 minutes.  Zero exposure was assumed for the unsampled time period of 119 minutes.
Recent events (2)
  • — I (S) $2040
  • — Z (S) $3000

1910.134 F02

Serious Gravity 1 1 instance 1 exposed
Issued
May 3, 2013
Abate by
Jun 20, 2013
Penalty
Initial $3,000 · Current $2,040 Reduced

Hazardous substances 1591

29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested whenever a different respirator facepiece (size, style, model or make) was used:    a) At the facility, on or about March 6, 2013 -  An Aluminize Lead Pan Operator was wearing a full facepiece respirator while assissting in scraping lead dross and coal from the aluminize lead pan.  The Aluminize Lead Pan Operator was not fit tested for a full facepiece respirator.
Recent events (2)
  • — I (S) $2040
  • — Z (S) $3000

1910.1025 D02

Serious Gravity 5 1 instance 2 exposed
Issued
May 3, 2013
Abate by
May 3, 2013
Penalty
Initial $5,000 · Current $3,400 Reduced

Hazardous substances 1591

29 CFR 1910.1025(d)(2): An initial determination was not made to determine if any employee may be exposed to lead at or above the action level:    a) At the facility, on or about March 6, 2013 - The employer did not determine if during the operation of removing lead dross from the Aluminize Lead Pan whether the Aluminize Lead Pan Foreman was exposed to lead at or above the action level.    b) At the facility, on or about March 6, 2013 - The employer did not determine if during the operation of removing lead dross from the Aluminize Lead Pan whether an Aluminize Lead Pan Operator was exposed to lead at or above the action level.
Recent events (2)
  • — I (S) $3400
  • — Z (S) $5000

1910.1025 E01 II

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
May 3, 2013
Abate by
Jun 20, 2013
Penalty
Initial $0 · Current $0

Hazardous substances 1591

29 CFR 1910.1025(e)(1)(ii): For any employee who is exposed to lead above the permissible exposure limit for 30 days or less per year, the employer did not implement engineering controls to reduce the exposure to 200 micrograms per cubic meter:  a)  At the facility, on or before March 6, 2013 - The employer did not implement engineering controls while the Aluminize Lead Pan Foreman scraped lead dross and coal from the top of the Aluminize Lead Pan.  The Aluminize Lead Pan Foreman was exposed to an 8-hour TWA of 240.531 micrograms of lead per cubic meter of air.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1025 G02 V

Serious Gravity 1 1 instance 1 exposed
Issued
May 3, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1025(g)(2)(v): Contaminated protective clothing to be cleaned, laundered, or disposed of, was not placed in a closed container to prevent dispersion of lead outside the container:   a) In the lead protective clothing change area, on or about January 18, 2013 - Protective clothing worn by a 3 and 4 Operator while scraping lead dross and coal from the top of a lead pan was disposed of in an unsealed 55 gallon drum.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1025 G02 VII B

Serious Gravity 1 1 instance 1 exposed
Issued
May 3, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1025(g)(2)(vii)(B):  The employer did not include the following information on bags or containers of contaminated protective clothing and equipment in lieu of the labeling requirements in paragraphs (g)(2)(vii)(A) of this section:    CAUTION: CLOTHING CONTAMINATED WITH LEAD. DO NOT REMOVE DUST BY BLOWING OR SHAKING. DISPOSE OF LEAD CONTAMINATED WASH WATER IN ACCORDANCE WITH APPLICABLE LOCAL, STATE, OR FEDERAL REGULATIONS.  a) In the lead protective clothing change area, on or about January 18, 2013 - Protective clothing worn by a 3 and 4 Operator while scraping lead dross and coal from the top of a lead pan was disposed of in an unlabeled 55 gallon drum.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Johnstown Wire Technologies, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338371248.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.