JOHNSTOWN, PA —
OSHA Inspection: JOHNSTOWN WIRE TECHNOLOGIES, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of JOHNSTOWN WIRE TECHNOLOGIES, INC. in 124 LAUREL AVENUE, JOHNSTOWN, PA 15906 (NAICS 331222). OSHA activity number 338371248.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JOHNSTOWN WIRE TECHNOLOGIES, INC.
- Site address
- 124 LAUREL AVENUE
- City
- JOHNSTOWN
- State
- PA
- ZIP
- 15906
- Mailing
- 124 LAUREL AVENUE, JOHNSTOWN, PA 15906
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331222
- Employees
- 262
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.95 G06
- Issued
- May 3, 2013
- Abate by
- May 3, 2013
- Penalty
- Initial $3,000 · Current $2,040 Reduced
8111
General-duty citation text
29 CFR 1910.95(g)(6): The employer did not obtain a new audiogram annually for each employee exposed to noise at or above an 8 hour time weighted average exposure of 85 decibels: a) At the facility, on or about March 6, 2013 - Audiograms were not conducted annually for wire drawers. A Set 36 Wire Drawer was exposed to a dose of 90.77 %. 90.77 % is equivalent to 89.2 dBA (8-hour time weighted average). This noise survey was conducted on March 6, 2013 for a period of 450 minutes. Zero exposure was assumed for the unsampled time period of 30 minutes. b) At the facility, on or about March 6, 2013 - Audiograms were not conducted annually for wire drawers. A Set 4 Wire Drawer was exposed to a dose of 68.65 %. 68.65 % is equivalent to 87.2 dBA (8-hour time weighted average). This noise survey was conducted on March 6, 2013 for a period of 361 minutes. Zero exposure was assumed for the unsampled time period of 119 minutes.
Recent events (2)
- — I (S) $2040
- — Z (S) $3000
1910.134 F02
- Issued
- May 3, 2013
- Abate by
- Jun 20, 2013
- Penalty
- Initial $3,000 · Current $2,040 Reduced
1591
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested whenever a different respirator facepiece (size, style, model or make) was used: a) At the facility, on or about March 6, 2013 - An Aluminize Lead Pan Operator was wearing a full facepiece respirator while assissting in scraping lead dross and coal from the aluminize lead pan. The Aluminize Lead Pan Operator was not fit tested for a full facepiece respirator.
Recent events (2)
- — I (S) $2040
- — Z (S) $3000
1910.1025 D02
- Issued
- May 3, 2013
- Abate by
- May 3, 2013
- Penalty
- Initial $5,000 · Current $3,400 Reduced
1591
General-duty citation text
29 CFR 1910.1025(d)(2): An initial determination was not made to determine if any employee may be exposed to lead at or above the action level: a) At the facility, on or about March 6, 2013 - The employer did not determine if during the operation of removing lead dross from the Aluminize Lead Pan whether the Aluminize Lead Pan Foreman was exposed to lead at or above the action level. b) At the facility, on or about March 6, 2013 - The employer did not determine if during the operation of removing lead dross from the Aluminize Lead Pan whether an Aluminize Lead Pan Operator was exposed to lead at or above the action level.
Recent events (2)
- — I (S) $3400
- — Z (S) $5000
1910.1025 E01 II
- Issued
- May 3, 2013
- Abate by
- Jun 20, 2013
- Penalty
- Initial $0 · Current $0
1591
General-duty citation text
29 CFR 1910.1025(e)(1)(ii): For any employee who is exposed to lead above the permissible exposure limit for 30 days or less per year, the employer did not implement engineering controls to reduce the exposure to 200 micrograms per cubic meter: a) At the facility, on or before March 6, 2013 - The employer did not implement engineering controls while the Aluminize Lead Pan Foreman scraped lead dross and coal from the top of the Aluminize Lead Pan. The Aluminize Lead Pan Foreman was exposed to an 8-hour TWA of 240.531 micrograms of lead per cubic meter of air.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1025 G02 V
- Issued
- May 3, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1025(g)(2)(v): Contaminated protective clothing to be cleaned, laundered, or disposed of, was not placed in a closed container to prevent dispersion of lead outside the container: a) In the lead protective clothing change area, on or about January 18, 2013 - Protective clothing worn by a 3 and 4 Operator while scraping lead dross and coal from the top of a lead pan was disposed of in an unsealed 55 gallon drum.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1025 G02 VII B
- Issued
- May 3, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1025(g)(2)(vii)(B): The employer did not include the following information on bags or containers of contaminated protective clothing and equipment in lieu of the labeling requirements in paragraphs (g)(2)(vii)(A) of this section: CAUTION: CLOTHING CONTAMINATED WITH LEAD. DO NOT REMOVE DUST BY BLOWING OR SHAKING. DISPOSE OF LEAD CONTAMINATED WASH WATER IN ACCORDANCE WITH APPLICABLE LOCAL, STATE, OR FEDERAL REGULATIONS. a) In the lead protective clothing change area, on or about January 18, 2013 - Protective clothing worn by a 3 and 4 Operator while scraping lead dross and coal from the top of a lead pan was disposed of in an unlabeled 55 gallon drum.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Johnstown Wire Technologies, INC.
View Johnstown Wire Technologies, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 331222)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338371248.