Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: XTREME COIL DRILLING CORPORATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of XTREME COIL DRILLING CORPORATION in XTREME RIG 17 PERGAMOS #3-11-7-60, BRIGGSDALE, CO 80611 (NAICS 213111). OSHA activity number 338405038.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Xtreme Coil Drilling Corporation — free Get an email when a new federal OSHA severe-injury report for Xtreme Coil Drilling Corporation is published. One employer, no account, unsubscribe in one click.
Site address
XTREME RIG 17 PERGAMOS #3-11-7-60
City
BRIGGSDALE
State
CO
ZIP
80611
Mailing
16285 PARK TEN PLACE, SUITE 650, HOUSTON, TX 77084
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213111
Employees
15
Ownership type
A

5 citations on file for this inspection.

5(a)(1)

Deleted Serious Gravity 5 2 instances 6 exposed
Issued
Jul 8, 2013
Penalty
Initial $5,000 · Current $0 Reduced
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to crushing hazards associated with improperly maintained manual pipe tongs.     (a) Xtreme Coil Drilling, Pergamos #3-11-7-60, Briggsdale, CO  80611: On and prior to January 22, 2013, both the "make up" and "break out" tongs were operating with missing latch assist springs (4). As a result, an employee received a serious hand injury on or about January 10, 2013 after the gate on one of the tongs unexpectedly opened as torque was applied.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5000

1910.22 A01

Other-than-serious 1 instance 6 exposed
Issued
Jul 8, 2013
Penalty
Initial $3,000 · Current $5,000
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition.     (a) Xtreme Coil Drilling, Pergamos #3-11-7-60, Briggsdale, CO  80611:  On or about January 22, 2013, the 7 bank control manifold was leaking hydraulic fluid onto the rig floor. Condition exposed employees to slips and/or falls from the same level or down the stairs leading from the rig floor.
Recent events (2)
  • — I (O) $5000
  • — Z (S) $3000

1910.23 C01

Other-than-serious 3 instances 20 exposed
Issued
Jul 8, 2013
Penalty
Initial $4,000 · Current $5,000
29 CFR 1910.23(a)(8): Every floor hole into which persons can accidentally walk were not guarded:     (a) Xtreme Coil Drilling, Pergamos #3-11-7-60, Briggsdale, CO  80611: On or about January 22, 2013, the employer did not ensure the floor hole in front of the vee-door measuring 29" X 12" was covered or guarded to prevent employees from accidentally steeping into. Condition exposed employees to cuts, contusions, and or laceration injuries.    (B) Xtreme Coil Drilling, Pergamos #3-11-7-60, Briggsdale, CO  80611: On or about January 22, 2013, sections of missing wood rig mats exposed employees to accidentally steeping into the voids. Condition exposed employees to ankle and/or knee injuries.
Recent events (2)
  • — I (O) $5000
  • — Z (S) $4000

1910.23 C01

Serious Gravity 5 1 instance 20 exposed
Issued
Jul 8, 2013
Penalty
Initial $20,000 · Current $7,000 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:Note:  Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard.       (a) Xtreme Coil Drilling, Pergamos #3-11-7-60, Briggsdale, CO  80611: On or about January 22, 2013, the employer did not provide guardrails to prevent rig personnel from falling through the vee-door opening. This condition exposed employees to fall hazards of over 10 feet.Xtreme     Coil Drilling was previously cited for a violation of this Occupational Safety and health standard or its equivalent standard CFR 29 CFR 1910.23( c )(1) which was contained in OSHA inspection number 456015, citation number 1, item number 3, issued on October 12, 2012, with respect to a workplace located at Pergamos #8-41-7-60, Rig #19.
Recent events (2)
  • — I (S) $7000
  • — Z (R) $20000

1910.157 C04

Deleted Other-than-serious 1 instance 9 exposed
Issued
Jul 8, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(4): Portable fire extinguishers were not maintained in a fully charged and operable condition:  (a) Xtreme Coil Drilling, Pergamos #3-11-7-60, Briggsdale, CO  80611: On or about January 22, 2013, the 20 pound Ansul Sentry portable fire extinguisher located over the mud tank was not operational.  The pressure gauge indicated "recharge" was needed.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Xtreme Coil Drilling Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338405038.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.