BROWNSVILLE, TX —
OSHA Inspection: NATIONAL ELECTRIC COIL CO., L.P.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of NATIONAL ELECTRIC COIL CO., L.P. in 3330 E 14TH ST, BROWNSVILLE, TX 78521 (NAICS 335312). OSHA activity number 338414030.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NATIONAL ELECTRIC COIL CO., L.P.
- Site address
- 3330 E 14TH ST
- City
- BROWNSVILLE
- State
- TX
- ZIP
- 78521
- Mailing
- 3330 E 14TH ST, BROWNSVILLE, TX 78521
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 335312
- Employees
- 167
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.1001 G03 I
- Issued
- Jun 25, 2013
- Abate by
- Jul 17, 2013
- Penalty
- Initial $5,000 · Current $5,000
9020
General-duty citation text
29 CFR 1910.1001(g)(3)(i) or, in the alternative, 29 CFR 1926.1101(h)(3)(i)(A): The employer selected and provided to employees filtering facepiece respirators for the protection against asbestos fibers: On or about December 26, 2012, and times thereafter in the wire mill area, the appropriate respirator was not selected for employees exposed to airborne particulates containing up to 40% asbestos during the removal of the internal cavity of a bell annealer furnace. A filtering facepeice respirator was provided to some employees for protection against asbestos fibers.
Recent events (3)
- — C (S) $5000
- — F (S) $5000
- — Z (S) $5000
1910.1001 H01
- Issued
- Jun 25, 2013
- Abate by
- Aug 7, 2013
- Penalty
- Initial $5,000 · Current $5,000
9020
General-duty citation text
29 CFR 1910.1001(h)(1)or, in the alternative, 29 CFR 1926.1101(i)(1): The employer did not ensure that employees exposed to asbestos at concentrations greater than the TWA and/or excursion limit or where no negative exposure assessment was conducted wore appropriate work clothing and protective equipment: On or about December 26, 2012, and times thereafter, the employer did not provide protective work clothing to employees who were exposed to particulates containing up to 40% asbestos while removing the internal cavity of a bell annealer furnace in the wire mill area.
Recent events (3)
- — C (S) $5000
- — F (S) $5000
- — Z (S) $5000
1910.1001 J03 I
- Issued
- Jun 25, 2013
- Abate by
- Aug 7, 2013
- Penalty
- Initial $5,000 · Current $5,000
9020
General-duty citation text
29 CFR 1910.1001(j)(3)(i) or, in the alternative, 29 CFR 1926.1101 (k)(3)(i): The employer failed to exercise due diligence to inform employees of the location and presence of ACM and/or PACM: On or about the inspection dates and at times prior thereto, an assessment of the worksite was not performed to determine the presence, location and quantity of asbestos containing material or presumed asbestos containing material prior to employees working in areas where asbestos containing material was present.
Recent events (3)
- — C (S) $5000
- — F (S) $5000
- — Z (S) $5000
1910.1001 K05
- Issued
- Jun 25, 2013
- Abate by
- Aug 7, 2013
- Penalty
- Initial $5,000 · Current $5,000
9020
General-duty citation text
29 CFR 1910.1001(k)(5) or in the alternative, 29 CFR 1926.1101 (g)(3)(iii): The employer shoveled, dry swept, and/or cleaned up asbestos dry, although vacuuming or wet cleaning was feasible: On or about December 26, 2012, and times thereafter, in the wire mill area employees were exposed to airborne particulates containing up to 40% asbestos. Employees performed tasks such as dry sweeping and dry collecting of ACM debris with shovels during the removal of the internal cavity of a bell annealer furnace.
Recent events (3)
- — C (S) $5000
- — F (S) $5000
- — Z (S) $5000
1910.1001 D02 I
- Issued
- Jun 25, 2013
- Abate by
- Aug 7, 2013
- Penalty
- Initial $55,000 · Current $44,000 Reduced
9020
General-duty citation text
29 CFR 1910.1001(d)(2)(i) or, in the alternative, 29 CFR 1926.1101 (f)(2)(i): The employer did not perform initial monitoring of employees who were, or might reasonably be expected to be, exposed to airborne concentrations at or above the 8-hour TWA and/or excursion limits: On or about December 26, 2012, and times prior thereto, at the wire mill area, the employer did not conduct initial monitoring to ascertain expected exposures of employees who were disturbing asbestos containing material and exposed to airborne particulates containing up to 40% asbestos during the removal of the internal cavity of a bell annealer furnace.
Recent events (3)
- — C (W) $55000
- — F (R) $44000
- — Z (W) $55000
More inspections at National Electric Coil CO., L.P.
View National Electric Coil CO., L.P.'s full OSHA safety record →
More inspections in this industry (NAICS 335312)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338414030.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.