OSHA Inspection: THIEMS CONSTRUCTION COMPANY, INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of THIEMS CONSTRUCTION COMPANY, INC. in SR 28 & LAKEVIEW ACRES ROAD, MARYVILLE, IL 62062 (NAICS 237310). OSHA activity number 338440837.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Thiems Construction Company, INC. — free Get an email when a new federal OSHA severe-injury report for Thiems Construction Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
SR 28 & LAKEVIEW ACRES ROAD
City
MARYVILLE
State
IL
ZIP
62062
Mailing
4289 INDUSTRIAL DRIVE, ROXANA, IL 62084
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237310
Employees
4
Ownership type
A

5 citations on file for this inspection.

1926.20 B01

Serious Gravity 5 1 instance 2 exposed
Issued
May 6, 2013
Abate by
May 31, 2013
Penalty
Initial $3,500 · Current $3,500
29 CFR 1926.20(b)(1):     The employer did not initiate and maintain such programs as may be necessary to comply with this part.    Employees were exposed to electrical shock hazards while working near 7.2 kV power lines, and the employer did not develop and maintain programs to prevent such hazards.
Recent events (1)
  • — Z (S) $3500

1926.20 B02

Serious Gravity 5 1 instance 2 exposed
Issued
May 6, 2013
Abate by
May 31, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.20(b)(2):     The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s):    Employees were exposed to electrical shock hazards while working near 7.2 kV power lines, and the employer did not initiate and maintain progams which provided for frequent and regular inspections of the job site.
Recent events (1)
  • — Z (S) $0

1926.21 B02

Serious Gravity 10 1 instance 2 exposed
Issued
May 6, 2013
Abate by
May 31, 2013
Penalty
Initial $4,900 · Current $4,900
29 CFR 1926.21(b)(2):     The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury:    Employees were exposed to an eletrical shock when a Caterpiller Excavator, Model Number 328D was located within 10 feet of a 7.2 kV power line, and the employer did not provide instructions to each employee in the recognition and avoidance of unsafe conditions and the regulations of 29 CFR 1926.600(a)(6).
Recent events (1)
  • — Z (S) $4900

1926.600 A06 I

Serious Gravity 10 1 instance 2 exposed
Issued
May 6, 2013
Abate by
May 10, 2013
Penalty
Initial $4,900 · Current $4,900
29 CFR 1926.600(a)(6)(i):   For lines rated 50kV or below, a minimum of 10 feet was not maintained between the energized line and the equipment.   Employees were exposed to electrical shock hazards when the clearance between the 7.5 kV lines and the Caterpiller Excavator, Model 328D, was not maintained at least 10 feet.
Recent events (1)
  • — Z (S) $4900

1926.600 A06 IV

Serious Gravity 10 1 instance 3 exposed
Issued
May 6, 2013
Abate by
May 10, 2013
Penalty
Initial $4,900 · Current $4,900
29 CFR 1926.600(a)(6)(iv):     A person shall be designated to observe clearance of the equipment and give timely warning for all operations where it is difficult for the operator to maintain the desired clearance by visual means;    Employees are exposed to electrical shock hazards while working near a Caterpillar Excavator, Model Number 328D, which was operating under 7.2 kV power lines, and the company did not designate a person to observe clearance of the equipment under the lines and give a timely warning to maintain at least 10 feet from the lines.